Herunterladen Inhalt Inhalt Diese Seite drucken

Victron energy Phoenix 12/3000 Anleitung Seite 22

Vorschau ausblenden Andere Handbücher für Phoenix 12/3000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 65
Phoenix Inverter
INVERTER
Input voltage range (V DC)
Output
Cont. output power at 25°C (VA)
Cont. output power at 25°C (W)
Cont. output power at 40°C (W)
Cont. output power at 65°C (W)
Peak power (W)
Maximum efficiency (%)
Zero-load power (W)
GENERAL
Programmable relay
Protection
Common Characteristics
ENCLOSURE
Common Characteristics
Battery-connection
230 V AC-connection
Weight (kg)
Dimensions (hxwxd)
STANDARDS
Safety
Emission / Immunity
1) Can be adjusted to 60Hz; 120V/60Hz on request
2) Protection
3) Non linear load, crest factor 3:1
4) Multipurpose relay which can be set for general alarm, DC undervoltage or genset start signal
function
20
Downloaded from
www.Manualslib.com
(1)
(3)
(4)
(2)
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
manuals search engine
24/5000
19 – 33
Output voltage: 230 VAC ± 2%
Operating temp.: -40 to +65°C (fan assisted cooling)
Humidity (non-condensing): max 95%
Material & Colour: aluminium (blue RAL 5012) Protection: IP 21
M8 bolts (2 plus and 2 minus connections)
Screw clamp 13mm² (6 AWG)
444 x 328 x 240
EN 60335-1, EN 60335-2-29
EN 55014-1, EN 61000-3-2 / EN 55014-2, EN 61000-3-3
48/5000
38 – 66
Frequency
50 Hz ± 0,1%
:
5000
5000
4000
4000
3700
3700
3000
3000
10000
10000
94
95
30
30
Yes
Yes
a - g
30

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis