for the installer
Before installation, check
that the local distribution
conditions (gas type
and pressure) and the
appliance regulation are
compatible. The regula-
tion conditions of this
appliance are printed on
the label (or data plate).
Installation
This appliance is not
provided with a combu-
stion product discharge.
It is recommended that it
be installed in
sufficiently aerated
places, in terms of the
laws in force. The
quantity of air which is
necessary for combu-
stion must not be below
2.0 m
/h for each kW of
3
installed power.
See table of burner
power.
Positioning
(Fig. 3-4). The appliance
can be fitted into a
working area as
illustrated on the
corresponding figure.
Before positioning the hob,
fit the seal
around the
entire periphery of the hole
cut in the worktop.
Gas connection
(Fig. 2) Connect the
appliance to the gas
cylinder or to the install-
ation according to the
prescribed standards in
force, and ensure
beforehand, that the
appliance matches the
type of gas available.
Otherwise, see
"Adaptation to various
types of gas".
Furthermore, check that
the feed pressure falls
within
the
values
described on the table:
"User chacteristics".
Rigid/semi rigid metal
connection
Carry out the connection
with fittings and metal
pipes (even flexible
pipes) so as to obtain
counter stress the inner
parts of the appliance.
N.B. - when the instal-
lation has been carried
out, check the perfect
sealing of the entire
connection system, by
using a soapy solution.
Do not use naked flames
to check for gas leaks.
Electrical connection
(Fig. 5) Prior to carrying
out the electrical connec-
tion, please ensure that:
• the plant characteris-
tics are such as to fol-
low what is indicated
on the matrix plate
placed at the bottom of
the working area;
• that the plant is fitted
with an efficient earth
connection, following
the standards and law
provisions in force.
The earth connection
is compulsory in
terms of the law.
Should there be no cable
and/or plug on the
equipment, use suitable
absorption material for
the working temperature
as well, as indicated on
the matrix plate. Under
no circumstance must
the cable reach a tem-
perature above 50 ° C of
the ambient tempera-
ture.
If connecting directly to
the mains power supply,
fit a multi-pole switch of a
suitable size for the rated
capacity with a clearance
distance which completely
disconnects the power
line under overvoltage
category III conditions,
consistently with the
rules of installation (the
yellow/green earth wir
must not be interrupted).
The plug or omnipolar
switch must be easily
reached on the installed
equipment.
To avoid all risk, if
the power
cable becomes
damaged, it must
only be replaced by
the manufacturer, by
an authorised service
centre, or by a
qualified electrician.
6-7
6
7
After converting the
appliance to another
type of gas, indicate the
new conditions on the
appropriate label attached
to the appliance.