Disconnect the appliance from the power supply in the
event of malfunction and always before cleaning or
maintenance;
-
When not in use, disconnect the appliance from the
power supply and turn off the gas valve (if present);
-
Always check to make sure that the control knobs are
on the "•"/"
" setting when the appliance is not in use;
o
The following instructions are intended for the installer so
that the installation and maintenance procedures may be
followed in the most professional and expert manner
possible. Important: Disconnect the appliance from the
electrical supply before performing any maintenance
or regulation upkeep work.
Positioning the Cooktop
Important: this unit may be installed and used only in
permanently ventilated rooms in accordance with British
Standard Codes Of Practice: B.S. 6172 / B.S. 5440, Par.
2 and B.S. 6891 Current Editions. The following
requirements must be observed:
a) The room must be fitted with a ventilation system which
vents smoke and gases from combustion to the outside.
This must be done by means of a hood or electric
ventilator that turns on automatically each time the hood
is operated.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
b) The room must also allow for the influx of the air needed
for proper combustion. The flow of air for combustion
purposes must not be less than 2 m³/h per kW of
installed capacity. The supply of said air can be effected
by means of direct influx from the outside through a
duct with a inner cross section of at least 100 cm² which
must not be able to be accidentally blocked. Those
appliances which are not fitted with a safety device to
prevent the flame from accidentally going out must have
a ventilation opening twice the size otherwise required,
i.e. a minimum of 200 cm² (Fig. A). Otherwise, the room
can be vented indirectly through adjacent rooms fitted
with ventilation ducts to the outside as described above,
as long as the adjacent rooms are not shared areas,
bedrooms or present the risk of fire (Fig. B).
Installation Instructions for built-in
Directly to the Outside
-
Cut the power supply cord after disconnecting it from
the electrical mains when you decide to no longer use
the appliance.
The manufacturer will not be held liable for any
damages arising out of : incorrect installation or
improper, incorrect or unreasonable use..
Detail A
A
Examples of ventilation holes
for comburant air.
Fig. A
c) Intensive and prolonged use of the appliance may ne-
cessitate supplemental ventilation, e.g. opening a
window or increasing the power of the air intake system
(if present).
d) Liquidified petroleum gases are heavier than air and,
as a result, settle downwards. Rooms in which LPG
tanks are installed must be fitted with ventilation
openings to the outside in order to allow the gas to
escape in the event of a leak. Therefore, LPG tanks,
whether empty or partially full, must not be installed or
stored in rooms or spaces below ground level (cellars,
ect.). It is also a good idea to keep only the tank
currently being used in the room, making sure that it is
not near sources of heat (ovens, fireplaces, stoves,
etc.) that could raise the internal temperature of the
tank above 50°C.
Installation of Built-in Cooktops
The gas cooktops are equipped with type X degree
protection against overheating. Therefore, the appliance
can be installed next to cabinets, provided the height of
the cabinet does not exceed that of the hob. For proper
installation of the cooktop, the following guidlines must be
followed:
a) If the cabinet(s) located next to the cooktop are higher
than the cooktop itself, the cabinet(s) must be installed
at least 600 mm from the edge cooktop;
b) Hoods must be installed in accordance with the
instructions contained in the installation manual for the
hoods themselves, and no less than 650 mm from the
cooktop;
c) The cabinets installed next to the hood must be located
at a height of at least 420 mm from the top, (as shown
in Fig. C).
13
Adjacent
Room to be
Room
Vented
Enlarging the ventilation slot
between window and floor.
Fig. B