Specifications

Ambient/Operating Temperature
Power
Notes:
Approvals (verify against device nameplate)

Installation

Notes:
Page EN-2
Downloaded from
www.Manualslib.com
internal enclosure temperature (P343)
max. 81
ambient temperature
(surrounding enclosure volume)
flange temperature
process temperature
WARNING: Internal temperature must not exceed 81
• 24-230 V ac, +15%, 40-70Hz, 28 VA (11W) or 24-230 V dc, +15%, (9W)
This instrument features a universal power supply. Either ac or dc voltage may be
applied to the same terminals.
The equipment must be protected by a 15 A fuse or circuit breaker in the building
installation.
The circuit breaker or switch in the building installation, marked as the disconnect
switch, shall be in close proximity to the equipment and within easy reach of the
operator.
General:
CSA
, FM, CE, 3A Sanitary
US/C
Radio:
Europe, Industry Canada, FCC
Hazardous:
Europe;
U.S.;
Canada;
Lloyds Register of Shipping, categories ENV1, ENV2, ENV3, ENV5
The SITRANS LR 300 is to be used only in the manner outlined in this manual, otherwise
protection provided by the equipment may be impaired.
Installation shall only be performed by qualified personnel and in accordance with local
governing regulations.
This product is susceptible to electrostatic shock. Follow proper grounding procedures.
Do not use a Ground Fault Interrupt (G.F.I.) with the SITRANS LR 300. The ground path is
used for filtering purposes in conjunction with the universal power supply.
The use of Teflon tape or other appropriate sealant may be used to aid in sealing tapered
threaded connections for use in pressure applications.
SITRANS LR 300 – QUICK START MANUAL
manuals search engine
o
C
o
EEx de IIC T6
ATEX II 1/2G, EEx de IIT6 or EEx d IIC T6
Class I, Div. 1, Gr. A,B,C,D (Class I, Zone 1, IIC T6)
Class II, Div. 1, Gr. E,F,G
Class III
Class I, Div. 1, Gr. A,B,C,D (Class I, Zone 1, IIC T6)
Class II, Div. 1, Gr. E,F,G
Class III
wrench (to open
enclosure)
C! Warranty may be void.
7ML19985QA82