Service interval reminder
DE
The Service interval reminder function is an aid to carry out a safety check on your boiler at
regular intervals. This function will be enabled and reset by a service professional.
EN
FR
Once the display shows alternating "SEr" and days until service is due, then the
boiler service need to be arranged accordingly.
The days until next service is due can also be seen whenever switching to and
IT
from Frost protection.
NL
ES
Display shows alternating "SEr...duE" indicates that the service day has expired.
Thermostat can still be fully operated but warning remains until boiler service is
done.
PT
CS
Display shows alternating "SEr...duE" and "OFF" indicates that the service day
HU
has expired and the thermostat is switched off.
The thermostat can only be operated in Comfort mode for 60 minutes whenever
turning the knob or pressing the advance button.
PL
SV
FI
ZH
TR
EL
RO
DA
BG
A6V101035990_en--_e
2018-06-21
Subject to alteration
Parameter setting
Parameter setting mode
1.
Press LEARN on the rear for 5 seconds until "P01" appears.
2.
Press advance button and the parameter value on second line flashes and is
ready for adjustment.
3.
Adjust the parameter using setting knob.
4.
Press advance button once to confirm the setting.
5.
Rotate the setting knob clockwise to next parameter and repeat steps 2 to 4.
6.
Exit parameter setting mode by rotating the setting knob clockwise to "End"
and pressing advance button once.
Parameters:
·
P01 Control behaviour: 2-position 1K / 2-position 0.5 K / PID fast / PID slow
(factory-setting)
·
P02 Maximum temperature range
·
P03 Minimum temperature range
Siemens Building Technologies / HVAC Products