N°156 PRO
INSTRUCTIONS ONLY FOR QUALIFIED
PROFESSIONAL SPECIALISTS
1 5
WORK THAT MAY BE REQUIRED
ELECTRICAL INSTALLATION MUST BE CARRIED
OUT BY A PROFESSIONAL ELECTRICIAN
Before carrying out any other types of work, disconnect
the Sanicubic from the power supply.
PROBLEM
PROBABLE CAUSES
No motor starts and the mains
No power
GREEN LED is off (*)
The LED war
ning light is on
1 – Obstructed pump
2 –
Blocked Pump
The LED flashing warning light
Faulty detection system
PROBLEM
PROBABLE CAUSES
The motor does not start
Faulty electronic card
but override works + The LED
warning light on
Pump running continuously
1 – Obstructed Dip tube
2 – Pump discharge height too
high
Pump starting up
The non-return valve is
intermittently
leaking or broken
Alarm reset
(*) override
(**) Warning: if pumping height is high, 90° elbows should be avoided.
FAULT WARNING LIGHT TABLE
Fault
Probable
detected
causes
RED LED ON
1- Blocked
+ YELLOW
pumps
LED OFF
2- Blocked pumps
+ BUZZER
3- Problems with
the electric
motors
4- Too much
water flowing in
5- Faulty circuit
board
RED LED OFF
Mains supply fault
+ FLASHING
on the appliance
YELLOW LED
+ INTERMITTENT
BUZZER
SOLUTIONS
Check your electrical
connections
Press the override button
continuously to get the
pump working
Contact SFA after-sales service
SOLUTIONS
Contact SFA after-sales
service
1 – Remove obstruction from
the discharge pipe
2 – Check installation (**)
Clean or change the valves
The manual override (MO) button switches
off the red LED if the problem is solved
Remedial
action
1- Contact SFA
after-sales
service
Check the
electrical install
1 6
DISMANTLING
INSTRUCTIONS RESERVED EXCLUSIVELY
FOR QUALIFIED PROFESSIONAL SPECIALISTS
DISCONNECT THE UNIT FROM THE
POWER SUPPLY (the green indicator
light must be off).
A
16
A
B
C
16
B
C
D
E
16
D
E
F
16
16
11