Herunterladen Inhalt Inhalt Diese Seite drucken

Fiem MG 140/200 Betriebshandbuch Seite 19

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 48
LCD THERMOSTAT INCUBATION CALENDARY
Once one or more hatching cycles calendars are activated, the display will show, further than temperature and humidity values, the
counting of the total number of days & hours spent from the begin of the first hatching cycle.
Pressing the "P" button you will accede to the hatching cycles programming menu. The display will show different indications accor-
ding to the state of the running incubation cycle. If the cycle is not activated
Ciclo: Z ---d --h
SET=Inizio Ciclo (Z = number of the visualized cycle)
If the cycle is activated
By repeatedly pressing the 'P' button you will run through the 4 incubation cycles. Pressing the 'SET' button you can start or stop
the cycle of incubation displayed. It will be possible to "force" the display of a particular cycle, including those active on the working
screen (so not only the cycle started by longer) by pressing the' P ' key until you reach the cycle to be displayed, and letting the tool
go to time-out (about 30Sec).
For the models equipped with FIEM MINILCD THERMOSTAT
1. Product overview
A
B
2. Key functions
3. Functionality description
MiniLCD is able to control with ON-OFF method or PID algorithm the temperature (see paragraph 7) and with mode ON-OFF the
incubation humidity.
At power on, a welcome message will appear briefly followed by firmware version of the board.
MiniLCD will prompt the current temperature and by pressing the arrow UP or DOWN the relative humidity.
By pressing the SET button you can modify the temperature and humidity value already set.
In case temperature or humidity probe fail, or in case one of them isn't connected, in the relative visual mode will prompt ERR and
the output will not controlled.
MiniLCD has in addition two different menus, one for the user, where you can customize the basic functions, and one technical that
permit to setup the machine and adjust the probe.
During start-up, menu for setting the type of temperature control.
4. User setup
After you turn-on MiniLCD by pressing the
to temperature icon start blinking and display show the reference
temperature.
Now by pressing
or
• T. incubazione [5 .. 75] (default 30.0)
This parameter define the temperature that the machine must be maintened during the incubation period. The range of values you
can set is between 5 and 75 °C or equivalent in F.
You can save the value by pressing the
Val xx.x°C yy% V
CyZ XXXd YYh z
Z = Number of the hatching cycle visualized (1st, 2nd, 3rd..., ...)
XXX = Number of days elapsed since the beginning of the cycle
YY = Number of hours spent with reference to the running incubation day.
Ciclo:Z XXXd YYh
SET= Fine Ciclo_
C
Shows the inside temperature
Setting temperature and humidity reference values
Shows the inside humidity
+
Technical menu for the calibration parameters, measurement units
+
During start-up, menu for setting the type of temperature control
button, RED LED close
you can change the set temperature.
button, display will show the humidity value.
F
D
A. Power switch
B. Light switch
C. 3 digits display with dot separation value
G
D. temperature LED
E. humidity LED
F. selection button <arrow up> (temperature)
E
G. setting button
H
H. selection button <arrow down> (humidity)
19