actual rules via the replacement of the now forbidden mercury with colored liquid. Being this last one physically more volatile and
subject to fragmentations, sometimes invisible because of his discoloration, the result is that the new thermometers are less reliable.
Consequently we ask our esteem customers & distributors to pay the maximum attention before
using our thermometers, examining that there are no gaps visible in the liquide and while storing
caring them to be positioned vertically. The adequate room temperature for storing our thermo-
meters is comprised between 10°C to 30°C.
INSTRUCTIONS FOR EASY ASSEMBLING
AND CONNECTING NATURAL SURFACE HUMIDIFICATION SYSTEM
We are providing MG Range of a new practical humidification system delivered as a standard feature.
Humidification will be performed through a specially conceived basin with automatic constant level water flow and external accumu-
lation tank (fig.1).
• Place the plastic reserve tank (packed inside the machine), on top of the machine
• Connecting the water inlet pipe (fig. 2).
• Fill with water the outside reserve tank, the water will go down into
the inside basin where the level will remain automatic by the float valve
• The inside water basin is equipped with automatic float valve to maintain
a constant water level
• In order to regulate the humidity value, utilize the metal cover included
VERY IMPORTANT (ORDINARY MAINTENANCE):
In order not to incur in any sudden water loss by the internal water tank please make sure that the floating does not present any
malfunction that may obstruct its movement. so keep the float perfecly clean and free of any lime deposit. after each incubation cycle
put a solution of water 70% + white vinegar 30% inside the humidification tank for 2/3 hours. then disassemble the float, rinses it
and reassemble it making sure of its correct operation before a new use.
INSTRUCTIONS FOR EASY ASSEMBLING AND CONNECTION OF AUTOMATIC HUMIDITY (optional)
OPTION 1
The air humidification inside the incubator is performed by a special humidifier (ultrasounds nebulizer) which uses ultrasounds techno-
logy to atomize water & create a smoke effect without changing the operating temperature.
ULTRASOUNDS NEBULIZER ASSEMBLING AND PREPARATION
Remove the ultrasounds nebulizer by its carton box and place it on a flat level surface next to the incubator.
Remove the humidifier plastic tank and fill it with water and then place it again up to plastic base.
Connect the air injection pipe to the humidifier introducing then the opposite part of the same pipe for at least 2-3 cm inside the
special dedicated intake predisposed on the incubator.
OPERATION: Plug the humidifier power socket to the power outlet socket positioned on the control panel back side and switch on
the humidifier by selecting the option "ON" on the main switch ON/OFF. Adjust the steam injection flow intensity by the control knob
on the frontal part of the humidifier. Generally it's enough to keep the dial set to 60/70% but in case the settled humidity percentage
is not reached than we suggest to turn the knob to maximum position. A red light on the humidifier will warn about water shortage
on the tank. The ultrasounds nebulizer is driven by the LCD control panel. After the above mentioned steps for connecting the instru-
ment it's necessary to set up the required humidity value in order to allow the nebulizer automatic activation at each request of air
humidification coming from the LCD thermostat.
IMPORTANT:
• The humidifier shall be disconnected from any power outlet when filling the tank, during displacement and during cleaning
• The humidifier shall not be used without water, if there is no water in the tank switch the humidifier off.
• Do not fill the humidifier tank with any other liquid than water, do not add medicines and do not cover any opening
• Do not use it outdoors.
OPTION 2:
INTERNAL HUMIDIFICATION BY HOT WATER: By the option "Internal humidification by hot water" we have equipped the incubator
with an immersion resistance to be positioned inside the water tank; then connect the resistance, via the special plug, to the socket
placed on the rear of the control panel. The activation of the resistance will be piloted by the electronic control unit.
USE AND CALIBRATION
- Before using the machine, remember to clean it carefully inside and outside, as shown in paragraph no. 5;
- When the incubator is supplied with natural surface humidification system follow the instructions contained on the next paragraph.
- To switch the machine on, connect the electric plug into the wall outlet, push the master switch O/I and before loading the eggs,
wait until the incubator has reached the working temperature of 37.7°C (99, 7°F).
- The inside lighting of the machine is by a led lamp activated by the switch placed on the control panel; remember to switch off the
light while the machine is in operation.
- Take out the setting trays and place the eggs into setting tray with the points downwards
working temperature of 99.7°F, introduce the trays into the machine with the eggs positioned correctly
engage the end of the trays fully into the splits of the egg-turner bar; the egg turning device will be activated automatically when the
machine is switched on.
4
2
It is noted that in order to guarantee the embryonic development, the eggs must be placed with the air space towards the top.
3
Included in the equipment of the machine, there are some springs to be placed into single row of setting tray in order to stop the eggs in case it remains free space.
4
If the machine was supplied with manual egg-turner, remember to turn the eggs twice per day, morning and evening, using the key on setting trays.
16
Fig. 2
Fig. 3
. Only when machine has reached the
2
; taking particular care to
3
Fig. 1