Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 48
Now the GREEN LED close to humidity icon start blinking and display show the humidity percentage to be observed For modify the
humidity parameter pressing
• Umidità incubazione [10 .. 99] (default 40)
This parameter allows you to set the relative humidity to be maintained during the incubation period. The range of values that can be
set in this field is between 10% and 99%.
After editing the values MiniLCD automatically exits the edit menu if no buttons are pressed for 15 seconds by saving the value shown.
5. Technical setup
By simultaneously pressing
Its possible to read all parameters in sequence by pressing
To confirm the modify of the value press again
MiniLCD will exit automatically after 15 seconds if no keys are pressed by saving the value shown.
List of parameters showed by pressing
• Unit [C,F] (default °C) - Setting the temperature units Celsius or Fahrenheit
• t.CAL [-3,0 .. +3,0 °C] (default 0,0 - step di 0,1 °C)
t.CAL [-5,4 .. +5,4 F] (default 0,0 - step di 0,1 F) - It allows to calibrate the temperature read by the probe, in Celsius or Fahrenheit
depending on the setting assigned at the previus point.
• H.Cal [-5 .. +5] (default 0 – step di 1%) - It allows to calibrate the humidity value read by the probe.
6. Control mode temperature
By pressing simultaneously
• Controllo [PID,v ON-OFF] (default PID) Allow you to select the type of temperature control.
• PID = Control PID
• ON-OFF = Control ON-OFF

7. CONNECTION DIAGRAM

Descrizione dei collegamenti:
A = Power supply terminal block (ELECTRIC SHOCK)
B = Power output humidifier terminal block (ELECTRIC SHOCK)
C = Power output heater (ELECTRIC SHOCK)
D = Hygrometer probe
E = Temperature probe
Warning: disconnect power supply before attempting and performing any conn.
HUMIDITY
The LCD electronic control unit can perform the digital reading of humidity expressed in RH% (range 20-99%) and, if connected to
an external ultrasound humidifier, it is a super-modern digitally-regulated automatic humidification systems. Generally for manual
humidity by surface, as already mentioned, it is enough to assemble the water system and fill the reserve water tank with tepid water
and wait for 2/3 hours in order to see the value indicated by the hygrometer. If the value is too low, it will be necessary to take away
the cover on the internal water basin; if the humidity reading is too high, it will be necessary to reduce the water surface, by using
the metal cover of the basin. It should be remembered that it is the surface area of the water which affects humidity, not the depth
of the container or the volume of water.
For manual humidification, during the hatching period, if it is not enough the total surface on internal water basin, introduce under the
hatching basket another small water basin.
Take note that at the beginning of incubation, the eggs contain 100% liquid and they do not need further humidity; when the embryo
grows at working temperature, it may* be necessary to give humidity because the internal liquid will evaporate. The humidity reading
in degrees Fahrenheit is shown by the wet bulb hygrometer. For conversion to % Relative Humidity (RH), please compare with the
table below.
N.B.: Note that the wet bulb hygrometer shows the lower temperature produced by the cooling effect of evaporation (in comparison
with the air temperature) and needs to be converted to % relative humidity (RH). For this reason if the bulb is dry it will show the air
temperature (not the humidity). Consequently it is necessary to check that the wick is always wet and correctly pulled onto the bulb.
We suggest also checking the condition of the wick, especially if in a hard water area, because the water calcification damages it and
may cause an inaccurate reading. Use of deionised or distilled water is recommended for wet-bulb use.
APPROX. HUMIDITY VALUES WHEN OPERATING AT 37.7°C (100°F) DRY BULB TEMPERATURE
HEN LIGHT BREED(LAYER)
HEN HEAVY BREED (BROILER)
PHEASANT - PARTRIDGE – QUAIL- RED LEG PARTRIDGE
TURKEY – GUINEA FOWL
GOOSE - DUCK (MALLARD,PEKIN, KHAKI CAMPBELL, WILD)
20
or
button.
and
you enter the technical menu.
.
button
and
you can access a special menu for change the mode of control temperature.
TYPE
, button, the modify of the parameter occur by pressing
INCUBATION
82°F = 47%
84°F = 52%
78-80°F = 38-43%
82-84°F = 47-52%
78-80°F = 38-43%
and
.
HATCHING
88°F = 62%
88°F = 62%
86-88°F = 56-62%
88°F = 62%
88°F = 62%

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mg 200/300

Inhaltsverzeichnis