Speed fan regulation (ref. mod. MG 140/200 rural)
Press the "Fan" key to enter the fan speed set up page, choose the set value 1,2 or 3 by the keys
again the key "Fan".
Speed 1 = lower fan speed suggested for breeding live animals in the first week of life.
Speed 2 = medium fan speed suggested for hatching period (last 2 days)
Speed 3 = maximum speed suggested during incubation period
The LCD control unit is equipped with 6 different incubation programs as follows:
GENERIC (0): generic program to manage temperature and humidity
INC.PALMIPEDS(1): specific for palmipeds,it allows to set an automatic lowering of temperature of 0,2°C each week.
DIAPAUSE (2): available with super plus lcd control, to manage egg-turning and temperatures
CAM/CLIME (3): specific for chamaleons/reptiles available only with CLIMA incubator models, it allows to manage 4 incubation
temperatures with timer
GERMINATOR (4): specific for Germinator models, it allows to manage lighting with timer
EXOTIC (5): specific for parrots/birds of prey
REP/TORTUGA (6): specific for reptile and turtles
The default is set by the factory on the program GENERIC (0)
In order to display on the display the various incubation programs press the
it will appear --- Modalità ciclo (programma),
key
- run all incubation programs
keys
and
to adjust the parameters
Technical menu
Pressing simultaneously both keys
To view a set value press the " SET key and, if required, change it by using the keys
The electronic instrument will automatically exit the programming menu if no keys are pressed for longer than 25 Sec.
Technical menu parameters list
• Unit Misura temp
[°C,°F] (default °C)
• Hour format
24h AM / PM
• Set Hour
• Inc. temp. min.
[5,0 .. 75,0] (default 25.0) Used to limit the minimum acceptable value in the parameter incubation temperature User Menu
• Inc. temp. max.
[5,0 .. 75,0] (default 40.0) Used to limit the maximum acceptable value in the parameter incubation temperature User Menu
• Alarm temp. min.
[5,0 .. 75,0] (default 30.0) Used to limit the minimum acceptable value in the parameter alarm temperature User Menu
• Alarm temp. max.
[5,0 .. 75,0] (default 40.0) Used to limit the maximum acceptable value in the parameter alarm temperature User Menu
• Alarm temp.hyst.
[0,1 .. 5,0] (default 0.1)
• Calib temp.probe
[-3,0 .. +3,0] (default 0.0) Used to calibrate the probe of temperature
• Humidity min.
[10 .. 90] (default 40)
• Humidity max.
[10 .. 99] (default 80)
• Humidity hyst.
[1 .. 20] (default 1)
• Cal. humid.probe
[-5 .. +5] (default 0)
• Language
[0 .. 1] (default 0)
• Type of fan
[1 .. 4] (default 1)
• Buzzer Mode
[0 .. 2] (default 2)
• 0 = Buzzer off
• 1 = Buzzer on for pressing the keys
• 2 = Buzzer on for pressing the keys and in case of high temperature alarm
• Cam Cycle Time
• Cam Time ON
• Cam Time OFF
• Light ON Time
• Light OFF Time
Default parameter VENT. to reset
INDICATIVE CONVERSION TABLE FROM FAHRENHEIT DEGREES (°F) TO CELSIUS (°C).
°F
°C
80
26,7
81
27,2
82
27,8
83
28,3
84
28,9
85
29,4
Take note that 1°F is equal to 0.56 °C, while 1°C is equal to 1.8 °F.
18
key
key
+
, you will access the "Technical menu".
Setting units of measurement degrees Celsius / Fahrenheit
Current time setting (hours and minutes)
Used to set up hysteresis (accuracy) of alarm temperature
Used to limit the minimum acceptable value in the parameter incubation humidity User Menu
Used to limit the maximum acceptable value in the parameter incubation humidity User Menu
Used to set up hysteresis (accuracy) of thehumidity regulation
Used to calibrate the probe of humidity
Used to choose the languages showed on the display (Italian / English)
Used to choose the motor fan model
Fan motor type
Used to set the operating mode of the buzzer.
ON-OFF cycle time (minutes)
ON time (minutes)
OFF time (minutes)
Light time ON logic output – LIGHTS
Light time OFF logic output – LIGHTS
Setting of default parameters/Pressing the FAN button all default parameters are set
°F
°C
°F
86
30,0
92
87
30,6
93
88
31,1
94
89
31,7
95
90
32,2
96
91
32,8
96,8
button and hold it pressed for 5 sec.,
- to enter the parameter settings of the selected program
to store the settled parameter
1
MG50-MG70-MG100-MG140
2
3
MG500-432-576-720-MG400H
4
°C
°F
33,3
97
33,9
98
34,4
98,6
35,0
99
35,6
100
36,0
100,4
and
and confirm pressing
and
and memorize by "set".
Incubator model
MG244
Free channel
°C
°F
36,1
101
36,7
102
37,0
102,2
37,2
103
37,8
104
38,0
105
°C
38,3
38,9
39,0
39,4
40,0
40,6