IMPORTANT: Two days before hatching, remember to remove the eggs from the setting trays into the hatching basket.
LOAD EGGS STORED NOT MORE THAN 7-8 DAYS AND NOT LESS THAN 3 DAYS FROM LAYING.
BEFORE INCUBATION, THE EGGS MUST BE STORED IN A LOCATION WITH TEMPERATURE BETWEEN 14 – 16 °C.
FIEM LCD CONTROL PANEL
The new FIEM LCD control system provides a range of useful and easy-to-use extra features like temperature and humidity control
by proportional, integrative and derivate system (PID) or ON/OFF and temperature alarms.
When switched on the control system displays for some seconds the software version.
The electronic control unit with backlit LCD will show at the same time the operating temperature & humidity set up by the user along
with the effective values of temperature and relative humidity measured by the probes.
Ventilation intensity is fully and digitally adjustable according to the different incubation phases.
DESCRIPTION:
Temperature
reading
Master
switch
Light
switch
In case of any error on temperature or humidity reading two asterisks (**) will appear on the display.
The electronic instrument has two setting parameters menus; the first one allows the user to adjust the main functions where possible
and the technical one allows the instrument configuration.
User menu: The operating temperature of the PID system, the high temperature alarm limit and the relative humidity can be easily
adjusted entering into the user menu by pressing the SET key. It's possible to view all parameters by pressing the SET key and to
change the setting, by pressing the keys "INCREASE"
If no keys are pressed for 25 seconds or longer, the electronic instrument will go out automatically from program menu.
User List Parameters menu
• Unit Measur temp.
[°C,°F] (default °C)
• Incubation temp. (default 37.7) This parameter determinates the temperature that the instrument must be maintained during
• Alarm temperatur (default 38.2) If the read temperature by the instrument reaches the setted one in this parameter, it will be
• Incubation humid (default 47)
Relative humidity
reading
Temperature set
point
Setting units of measurement degrees Celsius / Fahrenheit
incubation period. The range of the values that can to be setted in this scale is definited by the
parameters "Inc.temp.min." and "Inc.temp.max." showed in the technical menu.
switched on the acustic buzzer alarm in order to report a fault. This out will remain on until the
temperature does not decrease under the setted value – "Ist.temp.allarm.".
The range of values that can to be setted in this scale is definited by the parameters "Temp.alarm.
min." e "Temp.alarm.max." showed in the technical menu.
This parameter allows to set the relative humidity to be maintained during incubation period. The
range of setting values in this scale is definited by the parameters "Min.Humidity" and "Max.humi-
dity" showed in the technical menu.
Fan speed
set value
Relative
Decrease
humidity
set point
e "DECREASE"
and confirming with SET.
Increase
Mode
(Calendary)
Speed fan
regulation
Parameters