AP10T
Installation
Downloaded from
www.Manualslib.com
Fig. 5: Pin assignment
Data transfer RS485 interface
RS485 baud rate
115.2 kbit/s
57.6 kbit/s
19.2 kbit/s
Data transfer CAN interface
CAN baud rate
125 kbit/s
250 bit/s
500 bit/s
1 Mbit/s
Strand cross sections of lines ≥0.14 ... ≤0.5 mm².
Earthing connection (PE)
For protection against interference, the screens of the signal lines and the
power line must be connected on both sides. Potential differences cause
inadmissible currents on the screen. Install the PE connection
protective earth conductor potential between the plug connectors (see
Fig.
5). Use 6.3 mm flat connectors or cable lug with short strands 2.5 ...
4 mm² (not in the scope of delivery). For multiple setpoint displays we
recommend connecting the earthing to a ground bar
AP10T · Date 19.05.2016 · Art. No. 88088 · Mod. status 154/16
manuals search engine
max. bus network length
200 m
400 m
1200 m
max. bus network length
320 m
160 m
80 m
40 m
English
23
1
Bus IN
2
Bus OUT
PE connection
3
3
onto the
(see
Fig.
6).
1