Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Pentair Jung Pumpen HIGHLOGO Original-Gebrauchsanleitung

Mikroprozessor-steuerung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH

TECHNICAL DATA

Weight
Protection category
Operating voltage
Power consumption of control unit
Control fuse
Fuse alternating current output
High water alarm emergency supply (optional)
Terminals
Motor protection
Monitoring of rotational field / phase failure
Temperature range in operation
Temperature range in storage
Air humidity
Pressure switch
Compli potentiometer
Level sensor, input
Level sensor, supply voltage
Level sensor, final value measuring range
Level sensor, resolution of level measurement display
Level switch, input
High water alarm, input
Powered alarm relay
Potential-free alarm relay
Method used for measuring current
Current transformer
28
depending on type 4-6 kg
IP 44
1/N/PE x 230 V, 50 Hz
3/N/PE x 400 V, 50 Hz
approx. 8 W
F1 fine-wire fuse 5x20 mm, 6.3 A T/MT; EN 60127-2-5, DIN 41571-2
F2 fine-wire fuse 5x20 mm, 2.0 A T/MT; EN 60127-2-5, DIN 41571-2
9 V NiMH rechargeable batteries
2.5 mm² push-in terminals on the PCB
4 mm² push-in terminals on top hat rail
Screw terminals 4 mm² at the motor protection relay/motor contactor
Screw terminal 6/10 mm² for potential equalisation
Motor protection switch on top hat rail / motor protection relay on
contactor
Error message given for anti-clockwise rotating field and if there is a
power phase failure
-20 ... 50°C
-20 ... 70°C
0 to 90% RH, with no condensation
0.005/0.01 bar, Pmax: 0.3 bar
5 kOhm
4 - 20 mA (two-wire) including stabilised supply voltage 24V
24 V
200-600 cm head of water, ± 2%
1 cm
24 V, 4 mA
12 V, 7 mA
230 V AC, max 2 A (AC1)
5A, 250 V AC
via current transformer and A/D converter
0 - 20 A, ± 10%

Quicklinks ausblenden: