Herunterladen Inhalt Inhalt Diese Seite drucken

Install Pressure Line; Start-Up; Fill The Pump; Checking The Air Pressure In The Stor- Age Vessel (Hw 3600) - AL-KO JET 3600 Betriebsanleitung

Hauswasserwerk/hauswasserautomat
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB
4.3

Install pressure line

1. Fasten the pressure line (04/1) to the pump
outlet.
2. Open all shut-off devices (valves, spray noz-
zles, water cock) in the pressure line.

5 START-UP

5.1

Fill the pump

IMPORTANT! Danger of damage to the
pump! Dry running will destroy the pump!
The pump must be filled with water up to the
overflow before each use so that it can draw
water immediately.
NOTE Fill the suction hose with water be-
fore screwing in place to reduce the suction time.
1. Open the filling screw (01-03/2).
2. Pour in water through the filling screw until
the pump housing (01-03/6) is full.
3. Screw in the filling screw.
5.2
Checking the air pressure in the storage
vessel (HW 3600)
IMPORTANT! Danger of damage to the
pump! The pump may only be operated with a
diaphragm storage pressure of 1.5 - 1.7 bar in
the storage vessel. Other diaphragm storage
pressures can cause equipment damage.
Check the air pressure at the valve on the
back of the storage vessel before commis-
sioning.
1. Open the shut-off device in the pressure line
(04/1).
2. Unscrew the cover (07/1) on the rear of the
storage vessel (03/10)
3. Check the air pressure at the valve (07/2) us-
ing an air pump or tyre filler equipped with a
pressure gauge.
4. Correct the air pressure to 1.5 - 1.7 bar, if
necessary.
5. Close the valve cover on the rear of the stor-
age vessel again.
6. Putting the pump into operation.
20

6 OPERATION

6.1

Switching the pump on

JET 3600
IMPORTANT! Danger of damage to the
pump! A closed pressure line can result in dam-
age to the pump!
Do not allow the pump to run against a
closed pressure line.
1. Open all shut-off devices (valve, spray noz-
zle, water cock) in the pressure line (04/1).
2. Insert the plug of the mains cable into the
power socket.
3. Switch on the pump at the on / off switch.
HW 3600
1. Open all shut-off devices (valve, spray noz-
zle, water cock) in the pressure line (04/01).
2. Insert the plug of the mains cable into the
power socket. The pumps starts to pump.
3. Close the shut-off device in the pressure line
when there are no more air bubbles in the es-
caping water.
The pump switches off automatically after
building up the pressure and reaching the
switch-off pressure.
The pump is ready for operation.
HWA 3600
1. Open all shut-off devices (valve, spray noz-
zle, water cock) in the pressure line (04/1).
2. Insert the plug of the mains cable into the
power socket. The pumps starts to pump.
Pump draws for three minutes.
Pump switches off for 30 seconds if no
water pumping is possible.
LED display
Pump draws again for three minutes.
Pump switches off permanently if no wa-
ter pumping is possible.
LED display
3. Allow the pump to cool down and fill up with
water if necessary.
4. Press the RESET button (06/1) to repeat the
procedure.
6.2

Switching the pump off

1. Switch the pump off.
Switch off the On/Off switch (JET 3600).
JET 3600 | HW 3600 | HWA 3600
Start-up
(06/2) flashes.
(06/2) lights up.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hw 3600Hwa 3600