  • DEUTSCH, seite 1
• Remove the draining screw (9) and drain all
water from the pump chamber. The water
contained in the reservoir will be pressed out by
the air bellows.
• Replace the draining screw and store the de
vice so that it is protected from frost.

Setting the pressure switch

The cut-in and cut-out pressures at which the sys-
tem starts and stops operating have been set in
the factory (see technical data). However, if
desired, you can adjust the setting as desired at
the pressure switch (10), also see Figure C.
• Unplug the electric cable from the socket.
• Remove the protective cover from the pressure
switch.
• Use a screwdriver to set the desired pressure:
A= Cut-in pressure
B= Cut-out pressure
Increase pressure = +
Decrease pressure = –
• Close the pressure switch by replacing the
cover.
• Put the system into operation and check the
changed pressures.
Please observe the max. permissible
pumping
height
technical data.
Checking the inlet pressure
• Unplug the electric cable from the socket.
• Open the pressure line and drain the water off
until the pump is completely empty.
• Check the inlet pressure at the diaphragm (5).
The pressure should be approx. 1.5 bar.
Correct the pressure if needed.
• Put the domestic water system into operation
as set out in the instructions.
and
pressure;
see
Disposal
Do not dispose of worn-out
units through the household
garbage!
RL 2002/96 EG
The appliance, its packaging and
accessories are all produced from
recyclable materials and must be
disposed of accordingly.
GB 4 