BRIDGED MODE
Output Definition
Load impedance or rated output voltage
Rated Load Impedance
isolated outputs only
Rated Output Power
THD<0.2%, 45Hz ... 20kHz
Maximum Bridged Output Power
THD=1%, 1kHz
GENERELLPower Requirements
Power Consumption
at 1/8 maximum output voltage @ rated load impedance
Protections
Input Connectors
Output Connectors
Cooling
Regulations
Safety Class
Operating Temperature Range
Mounting Depht with Connectors
Mounting Depht without Connectors
Dimensions (W x H x D)
Weight (net)
Downloaded from
www.Manualslib.com
manuals search engine
Direct Output
Isolated Outputs
8Ω
200V
140V
50V
——
57Ω
28Ω
3.6 Ω
560 W 700 W
700 W
700W
900W
820W
800W
780W
230V / 50Hz...60Hz
690 W
Audio limiters, High temperature, DC, HF, Back-EMF,
Peak current limiters, Inrush current limiters,
Turn-on delay, Output Transformer Saturation Protection
Euro-style, 3pin, detachable or XLR
Euro-style, 12pin, detachable, covered
Front-to-Rear, 3-stage-fans
The appliances are in accordance with EN60065, EN50081-1, EN 50082-1
I
+5°C ... +40°C
437 mm
377 mm
483mm x 132.5mm x 382mm
20.5 kg
28
Direct Output
Isolated Outputs
8Ω
200V
140V
——-
40Ω
19.6Ω
600W
1000W
1000W
1200W
1180W
1160W
120V/230V / 50Hz...60Hz
870 W
22.5kg
50V
2.5 Ω
1000W
1140W