Storage
m Important!
Pull out the mains plug and ventilate the equip-
ment and all connected pneumatic tools. Switch
off the compressor and make sure that it is se-
cured in such a way that it cannot be started up
again by any unauthorized person.
m Important!
Store the compressor only in a dry location
which is not accessible to unauthorized persons.
Always store upright, never tilted!
Releasing excess pressure
Release the excess pressure by switching off the
compressor and using the compressed air which
is still left in the pressure vessel, e.g. with a com-
pressed air tool running in idle mode or with a blow-
out pistol.
Storage power cord, hose and accessories
(Fig. 3/4)
• The power cord can be stored sideways of the com-
pressor.
• The air hose can be stored in the tool cmpartment.
• On the inside of the tool compartment (10) can be
stored accessories.
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: belt, coupling
* Not necessarily included in the scope of delivery!
Troubleshooting
Fault
Possible cause
The compressor does
• No supply voltage.
not start.
• Insuffi cient supply voltage.
• Outside temperature is too low.
• Motor is overheated.
The compressor starts
• The non-return valve leaks.
but there is no pres-
• The seals are damaged.
sure.
• The drain plug for condensation water
The compressor starts,
• The hose connections have a leak.
pressure is shown on
• A quick-lock coupling has a leak.
the pressure gauge, but
• Insufficient pressure set on the pressure
the tools do not start.
www.scheppach.com service@scheppach.com +(49)-08223-4002-99 +(49)-08223-4002-58
leaks.
regulator.
Disposal and recycling
The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in
this packaging can be reused or recycled. The equip-
ment and its accessories are made of various types
of material, such as metal and plastic. Defective
components must be disposed of as special waste.
Ask your dealer or your local council.
Old devices must not be disposed of with house-
hold waste!
This symbol indicates that this product must
not be disposed of together with domestic
waste in compliance with the Directive
(2012/19/EU) pertaining to waste electrical
and electronic equipment (WEEE). This product must
be disposed of at a designated collection point. This
can occur, for example, by handing it in at an author-
ised collecting point for the recycling of waste elec-
trical and electronic equipment. Improper handling
of waste equipment may have negative consequenc-
es for the environment and human health due to po-
tentially hazardous substances that are often con-
tained in electrical and electronic equipment. By
properly disposing of this product, you are also con-
tributing to the effective use of natural resources.
You can obtain information on collection points for
waste equipment from your municipal administration,
public waste disposal authority, an authorised body
for the disposal of waste electrical and electronic
equipment or your waste disposal company.
Remedy
• No supply voltage.
• Insufficient supply voltage.
• Outside temperature is too low.
• Motor is overheated.
• The non-return valve leaks.
• The seals are damaged.
• The drain plug for condensation water leaks.
• The hose connections have a leak.
• A quick-lock coupling has a leak.
• Insufficient pressure set on the pressure
regulator.
19 | GB