Herunterladen Diese Seite drucken

SICK WT24-2 Betriebsanleitung Seite 11

Vorschau ausblenden Andere Handbücher für WT24-2:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
8008784.Z474 | SICK
Subject to change without notice
The minimum distance (= y) for background suppression can be determined from diagram
[
figure 6
1] as follows:
Example: x = 600 mm, y = 4.5 => 4.5% of 600 mm = 27 mm. That is, the background is
suppressed at a distance of > mm from the sensor.
y
10
8
6
6%/90%
1
4
2
0
mm
200
400
600
Figure 6: WT24-2Xx4x, -2Xx5x
1
2
3
Figure 8: Description of the
Non-defined range
1
Sensing range (adjustable range), max. on black (6%)
2
Minimum distance between set sensing range and background
3
Table 8: Values for figure 8
WT24-2
xx4x, xx5x
0 ... 100 mm
1
100 ... 600 mm
2
≥ 40 mm / 600 mm
3
WT24-2xx4x, WT24-2xx5x: visible red light
WT24-2xx1x, WT24-2xx2x: infrared light, not visible
3
Sensing range setting
Sensor with potentiometer: open the sensor cover and protective hood, make sure that no
dirt has gotten into the sensor.
The sensing range is adjusted with the potentiometer (type: without stop ). Clockwise rota‐
tion: sensing range increased; counterclockwise rotation: sensing range reduced. We rec‐
ommend placing the object within the sensing range, e.g. see
range has been adjusted, the object is removed from the path of the beam, which causes
the background to be suppressed and the switching output to change [see
table
7].
Table 9: Sensing range setting
y
10
8
6
18%/90%
2
4
90%/90%
2
3
x
0
800
1000 1200 1400
mm
Distance in mm
COMMISSIONING
6%/90%
18%/90%
1
2
90%/90%
500
1000
1500
2000
2500
Distance in mm
Figure 7: WT24-2Xx1x, -2Xx2x
xx1x, xx2x
0 ... 100 mm
100 ... 1300 mm
≥ 70 mm / 1300 mm
table
9. Once the sensing
table 3
6
3
x
3000
and
11

Werbung

loading