the state of the automation process. Light off automation closed,
access open, slow flashing motor open, fast flashing motor closing.
Functioning of the Flasher or courtesy light:
The control unit has an output for the use of a flasher of 12/24*Vdc 4W
max. Its use is conditioned by the settings selected in Extended Menu
2.
Electric lock control Output:
The control unit has an output for the use of electric locks of 12/24*Vdc
12W max. It is activated for 2 seconds during each initial opening
phase.
Buffer battery:
The control unit has an incorporated 13.7 Vdc battery charger (you need
to use 12V batteries, even for 24V motors). The control unit can be fit-
ted with a buffer battery not exceeding 7Ah in capacity, which can be
used for up to 20/30 complete phases. The flashing light, if fitted, turns
on for only the first 4 seconds of the phase in the event of a power cut.
Solar panel:
The control unit can be fitted with a solar panel for charging the emer-
gency battery.
Operation with TIMER:
The control unit may be connected to a timer instead of using the open-
close command button (PUL).
Example: at 8:00 a.m. the timer closes the contact and the control unit
opens the gate; at 6:00 p.m. the timer opens the contact and the con-
trol unit closes the gate. Between 8:00 a.m. and 6:00 p.m. at the end of
the opening phase, the control unit disables the flashing beacon, the
automatic closing stage and the radio controls.
PROGRAMMING:
SEL key: selects the type of function to be stored; selection is indicat-
ed by a flashing LED.
By pressing the key repeatedly, you can select the desired function. The
selection remains active for 10 seconds (indicated by the flashing LED);
after 10 seconds, the control unit returns to its original status.
SET key: programmes the information according to the type of function
selected previously using the SEL key.
IMPORTANT: The function of the SET key can be replaced with the
radio control, if programmed previously (CODE LED on).
MAIN MENU
The control unit is supplied by the manufacturer with the option of
selecting a number of principal functions.
MAIN MENU
Led reference
Led off
1) TIPO MOTOR
Linear
2) AUTO PGM
Automatic PGM = OFF
3) CODE
No code
4) CODE PED.
No code
5) T. MOT.
30 sec. activity
6) T.MOT.PED.
10 sec. pedestrian activity Programmed delay
7) T. PAUSA.
No automatic close
8) RIT. ANTE
No gate delay
1) TYPE OF MOTOR:
The control unit has, by default, the operating logic for connecting lin-
ear actuators (TIPO MOTORE Led off). To enable the operating logic for
connecting variable consumption motor reducers (TIPO MOTORE Led
on), proceed as follows: press the SEL button until the TIPO MOTORE
Led flashes, then press the SET button. The TIPO MOTORE Led turns
on and remains steady. Repeat the procedure to restore the previous
configuration.
2) AUTO PGM:
The control unit allows you to execute (Simplified) Automatic
Programming.
Firstly, move the gates to their half-way position, press the SEL button
until the AUTO PGM flashes, then press and hold the SET button; Motor
2 executes the closing phase up to the limit switch or stop, and then
Motor 1 does the same. If the motors move in the wrong direction,
release the SET button, unplug the control unit and connect the wires
properly to the motors. If instead the motors act as required, the con-
trol unit should execute a complete opening and closing phase and
therefore the entire auto programming procedure (you need to press
and hold the SET button until the end of the Auto Programming proce-
dure).
At the same time, the deceleration cycle is automatically configured at
15% of the complete cycle.
During automatic programming, you can use the radio control key on
the control unit instead of the SET key, if stored previously.
3) CODE: (Radio control code)
The control unit can store up to 150 radio controls with different fixed or
rolling codes.
Programming.
To programme the transmission code, proceed as follows: press the
SEL key until the CODE LED flashes and send the desired code with the
relevant radio control; programming is completed when the CODE LED
turns on and remains steady. If you have stored 150 codes and you
repeat the programming operation, all the programming LEDs will start
flashing to indicate that no more codes can be stored.
Deleting the codes.
All the stored codes are deleted as follows: press the SEL button until
the CODE led flashes, then press the SET button and the CODE led
turns off and the codes are deleted.
4) CODE PED: (Pedestrian radio control code)
The programming and deleting procedure is the same as the one illus-
trated above except that the led selected should be CODE PED.
5) MOTOR TIME and DECELERATION: (Programming a motor opera-
tion time of max 4 minutes)
The control unit is supplied by the manufacturer with a default motor
operation time of 30 seconds, without deceleration.
To modify the operation time of motors 1 and 2, proceed as follows
when the gate is closed: use the SEL key to navigate to T.MOT when
the respective LED is flashing, then press the SET key briefly and motor
1 will begin its opening cycle; when the initial point of deceleration is
reached press the SET key again: the T.MOT LED will start flashing
more slowly and motor 1 will decelerate; when the desired position is
reached, press the SET key to complete the opening cycle. The T.MOT
LED now starts flashing normally again and motor 2 will begin its open-
ing cycle; program the work time for Motor 2, following the same
instructions as for Motor 1. After programming the opening times for
the motors, motor 2 will start its closing cycle: repeat the same instruc-
tions as above for programming the closing cycle of motor 2 and then
for motor 1.
To deactivate the deceleration function during programming, once the
opening and closing cycle is completed, press the SET key twice in
succession instead of just once.
When programming, you can use the radio control key on the control
unit instead of the SET key, if stored previously.
Led on
Variable
6) T. MOT. PED: (Programming pedestrian operation time of max 4 min-
Automatic PGM = ON
utes)
Code activated
The control unit is supplied by the manufacturer with predefined opera-
Code activated
tion time of Motor 1 (Pedestrian) of 10 seconds without deceleration.
Programmed delay
To modify the pedestrian operation time, follow this procedure with the
shutter closed: with the SEL key go to T.MOT.PED. LED when flashing,
Automatic close
then press the SET key rapidly, Motor 1 starts the opening cycle; when
Programmed delay
the initial point of deceleration is reached press the SET key again, the
motor decelerates until the desired position is reached, press the SET
key to complete the opening cycle. The T.MOT.PED LED starts flashing
rapidly, now repeat the programming operation for closing. To deacti-
vate the deceleration function, during programming, once the opening
and closing cycle is completed, press the SET key twice in a sequence.
During programming the radio control key of the control unit can be
used instead of the SET key, if stored previously.
7) T. PAUSA: (Programming the aut. Closing time – 4 min max.)
The control unit is supplied by the manufacturer without an automatic
closing procedure. To enable the automatic closing function proceed as
follows: use the SEL key to navigate to T. PAUSA when the respective
LED is flashing, then press the SET key again briefly; the automatic
closing time is stored and the T. PAUSA LED remains lit constantly.
To restore the initial configuration (without automatic closing) navigate
to T.PAUSA when the respective LED is flashing then press the SET key
twice within 2 seconds; the LED switches off and the operation is com-
plete.
When programming, you can use the radio control key on the control
unit instead of the SET key, if stored previously.
8) T. RIT. ANTE: (Programming door delay of max. 15 sec.)
The control unit is supplied by the manufacturer without door delay dur-
ing opening and closing. To programme the door delay time, follow this
- 7 -