Waiting mode ("STB", "STANDBY")
Depending on the system, only cells selected with the same charging current will be
charged simultaneously. Rechargeable batteries with differing charging currents are
shifted to the standby mode, until their activation ("STB"). Once all of the required
parameters are met, the charging step is automatically continued.
Display in the overview:
S1
S2
S3
CHA STB --- ---
Maintenance Charge ("TRI", "TRICKLE")
Batteries discharge over time. This property is known as self-discharge. To balance out
this loss, the "Charge manager 420" starts the maintenance charge programme "TRI"
("TRICKLE") automatically if needed. Of course, this does not apply if the battery was only
discharged with the programme "DIS" ("DISCHARGE"). The capacity (C) of the recharge
("TRICKLE") and the time required for this process ("HH:MM") will not be indicated or
summed up. Only voltage and current are updated. Therefore, the charging capacity, if
applicable the discharging capacity and the time only refer to the programme processed
previously.
Display in the overview:
S1
S2
S3
TRI --- --- ---
Defective battery ("ERR", "ERROR")
If the charge current is unsuccessful, the error message "ERR" ("ERROR") is output (see
chapter 15).
The charger will no longer process this battery.
Display in the overview:
S1
S2
S3
ERR --- --- ---
S4
S4
S4
49