Explanation of the Charging Stages
• 12V charger If the voltage is above 13.2 volts (pass), the
charger will proceed to the final stage: Float.
• 24V charger If the voltage is below 26.4 volts (fail), the
charger will initiate the Recondition stage.
6 - Recondition
Choose the Recond program to add the Recond step to the charg-
ing process. During the Recond step voltage increases to create
controlled gasing in the battery. Gasing mixes the battery acid and
gives back energy to the battery.
This recondition stage can recover batteries from a deeply dis-
charged state increasing performance and battery life.
RECONDITION - This mode is used to recover deep discharged
flooded batteries where you could expect a stratified acid (high
acid weight in the bottom, low on top). Check with battery manu-
facturer when in doubt.
Use this mode with care, because the high voltage will cause
some water loss. 16V/32V is normally no problem for electronics
in 12V/24V system. Consult your supplier when in doubt. Life of
light bulbs will be reduced at higher voltage. Try to disconnect light
from the battery during this phase. Maximum effect and minimum
risk for electronics is achieved by charging a disconnected battery.
7 - Float
The Float stage maintains the battery at 100% charge without
overcharging or damaging the battery. This means the charger can
be left connected to the battery indefinitely.