Charging Stages
GEL
1. Desul-
11 V / 22 V
phation
Half the rated
2. Soft
volatge up to
Start
12,5 V/ 25 V
100 %
current until
3. Bulk
14,1 V /
28,2 V
Constant volt-
age 14,1 V /
4. Absorp-
28,2 V until
tion
current drops
to 15 %
Checks if
voltage drops
5. Analyse
to 13,2 V /
26,4 V
Constant
current (15
6. Recon-
%) limited
dition
to 14,1 V /
28,2 V
13,7 V / 27,4
7. Float
V, 100%
current
Keeps volt-
age at 12,6
8. Pulse
V – 14,1 V or
25,2 – 28,2 V
at 100 %
AGM
WET
11 V / 22 V
11 V / 22 V
Half the rated
Half the rated
volatge up to
volatge up to
12,5 V/ 25 V
12,5 V/ 25 V
100 %
100 %
current until
current until
14,4 V /
14,7 V /
28,8 V
29,4 V
Constant volt-
Constant volt-
age 14,4 V /
age 14,7 V /
28,8 V until
29,4 V until
current drops
current drops
to 15 %
to 15 %
Checks if
Checks if
voltage drops
voltage drops
to 13,2 V /
to 13,2 V /
26,4 V
26,4 V
Constant
Constant cur-
current (15
rent (15 %)
%) limited
limited to 16
to 14,4 V /
V / 32 V
28,8 V
13,7 V / 27,4
13,7 V / 27,4
V, 100%
V, 100%
current
current
Keeps volt-
Keeps volt-
age at 12,6
age at 12,6
V – 14,4 V or
V – 14,7 V or
25,2 – 28,8 V
25,2 – 29,4 V
at 100 %
at 100 %
37
CALCIUM
DURATION
Max. 8
11 V / 22 V
hours
Half the rated
Max. 8
volatge up to
hours
12,5 V/ 25 V
100 %
current until
Max. 24
14,7 V /
hours
29,4 V
Constant volt-
age 14,7 V /
29,4 V until
30 Min.
current drops
to 15 %
Checks if
voltage drops
90 Sec.
to 13,2 V /
26,4 V
30 min or
4h depend-
ing on bat-
Constant cur-
tery voltage
rent (15 %)
(Calcium
limited to 16
model must
V / 32 V
enter Re-
condition
stage)
10 days
13,7 V / 27,4
Charge cycle
V, 100%
restarts
current
if voltage
drops
Keeps volt-
Charge cycle
age at 12,6
restarts
V – 14,7 V or
if voltage
25,2 – 29,4 V
drops
at 100 %