The MultiPlus-II models can be controlled from the Load Disconnect and
Charge Disconnect outputs by using the BMS CL 12-200 to MultiPlus cable
(article number ASS070200100) This cable must be wired to the remote on/off
connector of the MultiPlus-II (connect the black wire to the lower (-) terminal
and the red wire to the upper (+) remote on-off terminal). Both the Load
Disconnect and Charge Disconnect outputs of the BMS must be in 'High' state
in order for the MultiPlus-II to operate. After shutdown due to low battery
voltage, run the alternator or use a battery charger on the primary side of the
BMS to reset the system. The MultiPlus-II will then switch on and start
charging (if connected to an AC power source).