Analog 4...20mA Register
7.3.4
Modbus
Modbus
No.of
Register
Address
Byte
2201
2200
2203
2202
2205
2204
2207
2206
2209
2208
2211
2210
2213
2212
2215
2214
2217
2216
2219
2218
2221
2220
2223
2222
VA 5xx Modbus RTU Installation V1.09
Data
Description
Type
4-20mA CH1 Selected
4
UInt32
Value as index
4-20mA CH1 Unit index
4
UInt32
from unit table for above
selected Value
4-20mA CH1 Auto or
4
UInt32
Manual Range
4
UInt32
4-20mA CH1 Scale Low
4
UInt32
4-20mA CH1 Scale High
4-20mA CH2 Selected
4
UInt32
Value as index
4-20mA CH2 Unit index
4
UInt32
from unit table for above
selected Value
4-20mA CH2 Auto or
4
UInt32
Manual Range
4
UInt32
4-20mA CH2 Scale Low
4
UInt32
4-20mA CH2 Scale High
4-20mA CH1 and CH2
4
UInt32
Current on error as index
4-20mA number of
4
UInt32
available channels
Default
Read
Setting
Write
0 = not used
1 = Flow
1 or 2
R/W
2 = Velocity
3 = Temperature
Flow:
U_m3_h,U_Nm3_h,U_m3_m
in,U_Nm3_min,U_ltr_h,U_Nlt
U_m3_h
r_h,U_ltr_min,U_Nl_min,U_lt
(VA520 & VA
r_s,U_Nl_s,U_cfm,U_Ncfm,
570)
U_kg_h,U_kg_min,U_kg_s,U
R/W
U_m_s
_kW
(VA500 & VA
Velocity:
550)
U_m_s,U_Nm_s,U_Ft_min,U
_Nft_min
Temperature:
U_GRAD_C,U_GRAD_F
0 = AutoRange
0
R/W
1 = Manual Range
writable only if Manual
0
R/W
Range is selected
writable only if Manual
Max Speed
R/W
Range is selected
0 = not used
1 = Flow
3
R/W
2 = Velocity
3 = Temperature
Flow:
U_m3_h,U_Nm3_h,U_m3_m
in,U_Nm3_min,U_ltr_h,U_Nlt
r_h,U_ltr_min,U_Nl_min,U_lt
r_s,U_Nl_s,U_cfm,U_Ncfm,
U_kg_h,U_kg_min,U_kg_s,U
U_GRAD_C
R/W
_kW
Velocity:
U_m_s,U_Nm_s,U_Ft_min,U
_Nft_min
Temperature:
U_GRAD_C,U_GRAD_F
0 = AutoRange
-20
R/W
1 = Manual Range
writable only if Manual
100
R/W
Range is selected
writable only if Manual
Max Speed
R/W
Range is selected
0 = is the actual value
above 3.8mA or below
R/W
20.5mA
1 = 22mA is outputed
2 = 2mA is outputed
1
R
Seite 25 von 28