Modbus
Modbus
No.of
Register
Address
Byte
1141
1140
4
1143
1142
4
1145
1144
4
1147
1146
4
1149
1148
4
1151
1150
4
1153
1152
4
1155
1154
4
1157
1156
4
1159
1158
4
1161
1160
4
1163
1162
4
1165
1164
4
1167
1166
4
1169
1168
4
1171
1170
4
1173
1172
4
1175
1174
4
1177
1176
4
1179
1178
4
1181
1180
4
1183
1182
4
1185
1184
4
1187
1186
4
VA 5xx Modbus RTU Installation V1.09
Data
Description
Type
Float
Flow in Nltr/h
Flow Min in Nltr/h since last
Float
Clear Min/Max
Flow Max in Nltr/h since last
Float
Clear Min/Max
Float
Flow AV in Nltr/h
Float
Flow in ltr/min
Flow Min in ltr/min since last
Float
Clear Min/Max
Flow Max in ltr/min since last
Float
Clear Min/Max
Float
Flow AV in ltr/min
Float
Flow in Nltr/min
Flow Min in Nltr/min since last
Float
Clear Min/Max
Flow Max in Nltr/min since last
Float
Clear Min/Max
Float
Flow AV in Nltr/min
Float
Flow in ltr/s
Flow Min in ltr/s since last
Float
Clear Min/Max
Flow Max in ltr/s since last
Float
Clear Min/Max
Float
Flow AV in ltr/s
Float
Flow in Nltr/s
Flow Min in Nltr/s since last
Float
Clear Min/Max
Flow Max in Nltr/s since last
Float
Clear Min/Max
Float
Flow AV in Nltr/s
Float
Flow in cfm
Flow Min in cfm since last
Float
Clear Min/Max
Flow Max in cfm since last
Float
Clear Min/Max
Float
Flow AV in cfm
Read
Default
Unit /Comment
Write
R
R
R
AV over the Time from
R
AVTime Setup 1 to 1440
minutes
R
R
R
Average for time period
R
defined in AVTime Setup
„1 to 1440 minutes"
R
R
R
Average for time period
R
defined in AVTime Setup
„1 to 1440 minutes"
R
R
R
Average for time period
R
defined in AVTime Setup
„1 to 1440 minutes"
R
R
R
Average for time period
R
defined in AVTime Setup
„1 to 1440 minutes"
R
R
R
Average for time period
R
defined in AVTime Setup
„1 to 1440 minutes"
Seite 15 von 28