CAUTION
Be sure to grip the handle and side handle during
work. Do not hold by the slide grip during work.
If you pull it by mistake, the bull point could jump
out.
5. RCD
The use of a residual current device with a rated
residual current of 30mA or less at all times is
recommended.
HOW TO USE THE DEMOLITION HAMMER
(Fig. 2)
1. After placing the tip of the tool on concrete surface,
switch ON.
2. By utilizing the weight of the machine and by firmly
holding the demolition hammer with both hands,
one can effectively control the subsequent recoil
motion.
Proceed at a moderate work-rate, the use of too
much force will impair efficiency.
GREASE REPLACEMENT
This machine is of full air-tight construction to protect
against dust and to prevent lubricant leakage. This
machine can be used without grease supplement for an
extended period of time. However, perform the grease
replacement to maintain the service life. Replace the
grease as described below.
1. Grease Replacement Period
You should look at the grease when you change
the carbon brush (See item 4 in the section
MAINTENANCE AND INSPECTION). Ask for grease
replacement at the nearest authorized Hitachi Service
Center.
In the case that you are forced to change the grease
by yourself, please follow the following points.
2. How to replace grease
CAUTION
Before replacing the grease, turn the power off and
pull out the plug from the receptacle.
(1) Remove the crank cover and wipe off the old grease
inside (Fig. 3).
(2) Supply 35 g (the standard volume to cover the
connecting rod) of Hitachi Electric Hammer Grease
A to the crank case.
(3) After replacing the grease, install the crank cover
securely.
NOTE
The Hitachi Electric Hammer Grease A is of the low
viscosity type. When the grease is consumed,
purchase from an authorized Hitachi Service
Center.

MAINTENANCE AND INSPECTION

CAUTION
Be sure to switch power OFF and disconnect the
plug from the receptacle to avoid serious trouble.
1. Inspecting the tool
Since use of a dull tool will degrade efficiency and
cause possible motor malfunction, sharpen or
replace the tool as soon as abrasion is noted.
5
2. Inspecting the mounting screws
Regularly inspect all mounting screws and ensure
that they are properly tightened. Should any of the
screws be loose, retighten them immediately. Failure
to do so could result in serious hazard.
3. Maintenance of the motor
The motor unit winding is the very "heart" of the
power tool. Exercise due care to ensure the winding
does not become damaged and/or wet with oil or
water.
4. Inspecting the carbon brushes (Fig. 4)
The motor employs carbon brushes which are
consumable parts. Since an excessively worn carbon
brush can result in motor trouble, replace the carbon
brushes with new ones having the same carbon
brush No. shown in the figure when it becomes
worn to or near the "wear limit". In addition, always
keep carbon brushes clean and ensure that they
slide freely within the brush holders.
5. Replacing carbon brushes
Loosen the set screw and remove the tail cover.
Remove the brush caps and carbon brushes. After
replacing the carbon brushes, do not forget to
tighten the brush caps securely and to install the
tail cover.
6. Replacing supply cord
If the supply cord of Tool is damaged, the Tool
must be returned to Hitachi Authorized Service
Center for the cord to be replaced.
7. Service parts list
CAUTION
Repair, modification and inspection of Hitachi Power
Tools must be carried out by a Hitachi Authorized
Service Center.
This Parts List will be helpful if presented with the
tool to the Hitachi Authorized Service Center when
requesting repair or other maintenance.
In the operation and maintenance of power tools,
the safety regulations and standards prescribed in
each country must be observed.
MODIFICATIONS
Hitachi Power Tools are constantly being improved
and modified to incorporate the latest technological
advancements.
Accordingly, some parts may be changed without
prior notice.
GUARANTEE
We guarantee Hitachi Power Tools in accordance with
statutory/country specific regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling
instruction, to a Hitachi Authorized Service Center.
NOTE
Due to HITACHI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis