5. Commissioning, operation

Comply with all of the instructions on the packaging pertaining to removing
the transport locks.
Remove the magnetic switch from the packaging carefully!
When unpacking, check all parts for external damage.
Functional test before assembly:
KSR KUEBLER Operating instructions Magnetic Switch– MSA
The functional test is carried out to determine the proper
functioning of the switching contacts. You should discon-
nect the power connection between the control and the
switch before the test. You can determine the switching
condition e.g. with a continuity tester. You can carry out
the functional test by actuating the contact with a perma-
nent magnet in the switching area. For this, you should
approach the magnetic switch with the magnet. When do-
ing so, the contact should switch over.
During the functional test, unintentional processes can be
triggered off in the downstream control. Risk of physical
injuries and property damage. Competent technical staff
only should connect and disconnect power lines. Do not
operate Magnetic Switches in the immediate proximity of
powerful electromagnetic fields (distance should be at
least 1m).
Do not expose Magnetic Switches to strong mechanical
loads.
11