Herunterladen Diese Seite drucken

Agilent Technologies TwisTorr 704 FS serie Bedienungshandbuch Seite 266

Werbung

16
Instructions for Use
Pump Fixing
The following table describes, for each ISO-F flange, the required
number of steel screws class 12.9 and the tightening toque according
to Agilent's recommendations.
Tab. 3
FLANGE
ISO 160 F
The following table describes, for each CF flange, the required
number of screws class 12.9 and tightening torque according to
Agilent's recommendations.
The turbopump with ConFlat inlet flange must be fixed to the
vacuum chamber by means of the appropriate Agilent hardware. See
the appendix "Technical Information" for a detailed description.
Tab. 4
FLANGE
CFF8"
The TwisTorr 704 FS cannot be fixed by means of its base.
NOTE
266/334
SCREW SIZES
M10
N.
20
TwisTorr 704 FS User Manual / 87-901-051-01 (A)
N.
FIXING TORQUE
8
40 Nm
FIXING TORQUE
25 Nm

Werbung

loading