Automatic setting control (Start Up Wizard)
To change the functions, press button C. Rotate switch A to select the
desired function (yes/no).
The changeable variable flashes on the screen. To accept the change,
press button C.
1.
MODE LO = FLOOR HEATING HI = RADIATOR HEATING
2.
VAL
= valve operation direction, clockwise/anticlockwise – default
Ve
setting is clockwise (note arrow on the display)
3.
'RF' indicates the strength of the radio signal. The device keeps
calculating the mean value, i.e. the value changes slowly on the
display. IF THE VALUE INCREASES, THE SIGNAL IS OK! With long
distances, the device must be left in place for a while when testing
the radio connection range.
4.
'De
' restores the original settings. NOTE: 'De
fA
THE RADIO CONNECTION.
5.
When you choose YES, 'RU' appears on the screen. If you press
button C now, the device enters pairing mode, and unless the motor
unit is powered off for a moment, the 'PAIR FAIL' message appears.
6.
Go to the motor unit and power it off for 3 seconds. When the motor
unit is powered on again, the device will be in pairing mode for 1
minute.
7.
To exit the menu, press the ECO button (B ). To return to the installa-
tion menu, press button D.
8.
Mount the room unit in a suitable location with the supplied screws.
If the location has not been decided yet, the room unit can be placed
in vertical position on a table, for example, as long as air can circulate
around it.
9.
Choose the desired indoor temperature and let the device adjust for
a few minutes.
' ALSO RESETS