SPIROLINE HP
High-pressure system
1
SAFET Y NOTE
The product may only be used together with approved components from Interspiro in
accordance with the specifications in this manual. The product may only be used by
individuals in good health who have been trained in the use of respiratory protection
equipment. If the product is used by someone with a beard or long sideburns, there
is a risk of inadequate sealing. The apparatus must be maintained, serviced and
tested in accordance with the instructions in the user manual, service manuals and
operating instructions from Interspiro.
INTERSPIRO ACCEPTS NO LIABILIT Y FOR
MAINTENANCE AND REPAIRS DONE BY PERSONS WHO DO NOT POSSESS A SERVICE CERTIFICATE
ISSUED BY INTERSPIRO
PRODUCT COMBINATIONS OTHER THAN THOSE MARKETED BY INTERSPIRO
PRODUCT MODIFICATIONS OR ADAPTATIONS BY THIRD PARTIES
Changes may be made to this manual without prior notice. Visit www.interspiro.
com regularly for updates and information about products, documentation and
service bulletins. Exposure to extreme conditions, may require measures other than
those described in this manual. These safety instructions do not increase or affect
Interspiro's liability and warranty terms.
The breathing air with which the cylinders are charged must meet the requirements
according to EN 12021, being free from oil, toxic substances and having low humidity.
The Spiroline HP system must not be used under water. When a lifeline is required, a
fall arrest harness must be connected to the apparatus.
The duration time of a breathing apparatus depends on the amount of air in the
cylinder(s) and the air consumption, which varies with the user and is affected by the
workload.
If the ambient temperature is 0 °C or lower, ice on the outside may prevent the
warning whistle from working. Under such conditions, the pressure gauge of the
apparatus must be checked more often.
When working with a breathing apparatus that have two independent cylinders
mounted on the harness, both cylinders must be pressurized to the same working
pressure. Always open both cylinder valves when pressurizing the apparatus and
make sure that both cylinder valves are open when using the apparatus.
When using Spiroline HP together with a breathing apparatus, the pressure gauge of
the breathing apparatus must be checked regularly. No active warning is given if air is
consumed from the cylinder on the breathing apparatus.
When the apparatus is used with the Spiroline belt, no active warning is given if the
air supply via the air supply hose stops.
3