Check that the air supply hose is pressurised. Connect the quick coupling on
3.
the P+ regulator to the breathing apparatus. For versions with Interspiro quick
connection, lock it with the locking ring.
Open the cylinder valve on the breathing apparatus.
4.
NOTE! THE CYLINDER VALVE OF THE BREATHING APPARATUS MUST BE OPEN IN USE. THE P+ REGULATOR HAS A HIGHER
SECONDARY PRESSURE THAN THE NORMAL AIR SUPPLY PRESSURE FROM THE BREATHING APPARATUS. AS A RESULT, THE
AIR SUPPLY FROM THE BREATHING APPARATUS IS CLOSED IN NORMAL USE.
UNLESS THE P+ REGULATOR IS EQUIPPED WITH A WARNING WHISTLE THERE IS NO ACTIVE WARNING GIVEN TO THE USER
WHEN AIR IS TAKEN FROM THE BREATHING APPARATUS/QS BAIL-OUT SET AIR SOURCE. CONSEQUENTLY, THE PRESSURE
GAUGE ON THE BREATHING APPARATUS/QS BAIL-OUT SET MUST BE CHECKED REGULARLY.
PREPARATIONS FOR USERS OF THE SPIROLINE BELT
Undo the buckle and the belt.
1.
Don the belt and fasten the buckle.
2.
Grasp the straps and adjust the belt by pulling them until the belt is comfortable.
3.
Connect the breathing hose from the Spiroline belt to the breathing valve.
4.
Prepare and don the facemask in accordance with the instructions for the
5.
facemask.
Using one of the carbine hooks, attach the eyelet on the air supply hose in a
6.
suitable manner. The air supply hose must be attached in such a way that the end
couplings and the nipples are not bent or loaded, whatever the direction of the
load.
Check that the air supply hose is pressurised. Connect the quick coupling on the
7.
P+ regulator to the Spiroline belt. For versions with Interspiro connection lock it
with the locking ring.
4
DURING USE - INSTRUCTIONS FOR HANDLING OF THE DISTRIBUTION PANEL
Use the "OPEN" sign to identify the air source that is currently in use.
Check the pressure in the air source on the pressure gauge.
Check that the air supply hose is not kinked.
Prepare switching to the other air source.
When the warning whistle sounds, open the other air source.
5

HANDLING OF THE AIR SUPPLY HOSE

To avoid the risk of obstructions in the flow, it is important to coil up the air supply
hose in such a way that it is not kinked or twisted. It must be coiled in figure-eights
or over/underturns (half-hitches). Make sure that it is coiled without tension in the
direction of the hose. Interspiro offers a hose reel for easy coiling of the air supply
hose.