Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SPIROLINE MP
Medium pressure system
This product, supplying breathing air to the user, conforms to EN 14595-1, and is to be
used according local regulations.
Manufacturer:
Interspiro AB
Box 2853, 18728 Täby, Sweden.
1
SAFET Y NOTE
The product may only be used together with approved components from Interspiro in
accordance with the specifications in this manual. The product may only be used by
individuals in good health who have been trained in the use of respiratory protection
equipment. If the product is used by someone with a beard or long sideburns, there
is a risk of inadequate sealing. The apparatus must be maintained, serviced and
tested in accordance with the instructions in the user manual, service manuals and
operating instructions from Interspiro.
INTERSPIRO ACCEPTS NO LIABILIT Y FOR
MAINTENANCE AND REPAIRS NOT CARRIED OUT BY A HOLDER OF A VALID INTERSPIRO CERTIFICATE.
COMBINATIONS OF PRODUCTS, UNLESS PUT TO MARKET BY INTERSPIRO
CHANGES OR ADAPTATIONS MADE TO THE PRODUCT BY A THIRD PARTY
Changes may be made to this manual without prior notice. Visit www.interspiro.com
regularly for updates and information about products, documentation and service
bulletins. Exposure to extreme conditions, such as asbestos, may require measures
other than those described in this manual. These safety instructions do not increase
or affect Interspiro's liability and warranty terms.
The breathing air with which the cylinders are charged must meet the requirements
according to EN 12021, being free from oil, toxic substances and having low humidity.
The Spiroline MP system must not be used under water. When a lifeline is required, a
fall arrest harness must be connected to the apparatus.
The duration time of a breathing apparatus depends on the amount of air in the
cylinder(s) and the air consumption, which varies with the user and is affected by the
workload.
If the ambient temperature is 0 °C or lower, ice on the outside may prevent the
warning whistle from working. Under such conditions, the pressure gauge of the
apparatus must be checked more frequently.
When working with breathing apparatus with two independent cylinders, both
cylinders must be pressurized to the same working pressure. Always open both
cylinder valves when pressurizing the apparatus and make sure that both cylinder
valves are open when using the apparatus.