Capacity
* ≤ 6nF not specified
* Overvoltage protection: 300Vrms
Diode
Continuity
test
* Overvoltage protection: 300Vrms
Range
60.00nF
600.0nF
6.000µF
60.00 µF
600.0 µF
4000 µF
Test condition
Test current of 1,5 mA
typical;
Open circuit voltage
<3VDC typisch
Test condition
Test current of < 0,35mA
-24-
Resolution
Accuracy
0.01nF
0.1nF
1nF
0.01 µF
0.1 µF
1 µF
Measurement of the
passage direction
Buzzer makes a long
sound while the
resistance is less than
50
± 3% + 5 dig.
± 3,5% + 10 dig.
± 5% + 10 dig.
Reading
Reading