Herunterladen Inhalt Inhalt Diese Seite drucken

Klarstein Iceblock Ecosmart 7 10034656 Gebrauchsanleitung Seite 37

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Problem
The unit does not cool
properly.
The unit is very loud.
Error codes
E1
The temperature sensor of the
capacitor is defective.
E2
The water tank is full during cooling.
E3
The temperature sensor of the
evaporator is defective.
E4
When heating, the water tank is full.
Possible cause
The doors or windows
weren't closed properly.
There are heat sources in
the room.
The exhaust hose has
not been connected or is
blocked.
The temperature setting is
too high.
The air inlet is blocked.
The floor of the site is not
level or flat enough.
The noise is caused by
the refrigerant circulating
inside the fan.
Replace the temperature sensor of the
capacitor.
Remove the rubber plug and drain
the water.
Replace the evaporator temperature
sensor.
Empty the water tank.
Suggested solution
Make sure all doors and
windows are closed.
If possible, remove the
heat sources.
Connect or clean the hose.
Reset the temperature
setting.
Clean the air inlet.
If possible, place the unit
on a flat, flat surface.
This is normal.
EN
37

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Iceblock ecosmart 7 10034658

Inhaltsverzeichnis