Herunterladen Inhalt Inhalt Diese Seite drucken

Starting Up The Time Switch; Switching Loads On/Off Manually; Activating Program Memories; Using The Timer Function - merten 5800 Gebrauchsanleitung

Zeitschaltuhr
Vorschau ausblenden Andere Handbücher für 5800:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Starting up the time switch

Switching loads on/off
manually
All information about the assembly
and installation of the insert and the
You can also switch loads on or off
time switch can be found in the
manually, regardless of programmed
instructions for the insert.
switching times, sun protection or
twilight functions.
The time switch is operational when
the mains voltage is switched on. The
– Switching on: Press the [EIN] (ON)
time display flashes.
– Switching off: Press the [AUS]
First perform a reset in order to delete
all data and restore the device to
Loads can also be operated by an
factory settings.
extension input (see insert manual).
1 Press the [Mode] and [Set] buttons
|
simultaneously for about
7 seconds, until all symbols in the
display go out.
The reset has been performed and the
factory settings are loaded (see
Activating program
„Program memory and switching
memories
times", p. 30).
Now program the date and time (see
As described in „Program memory and
„Setting the time and date", p. 40).
switching times", p. 30, you can save
up to 18 switching times, shared as
required between program memories
[A] or [B]. Program memory [C] is
dedicated to the timer function (see
„Using the timer function", p. 36).
To activate a program memory and the
switching times it contains:
1 Press [Mode] until the symbol for
Starting up the time switch
button.
(OFF) button.
Note: Manual or automatic
switching is blocked on the time
switch itself while the extension
unit is in use.
the required program memory [A] or
[B] appears in the display.
35

Using the timer function

Switching on loads with the
Prog Zufall Astro
A
timer function
Mode
Uhr
1 Press [Mode] until program
Mode
OFF
W
Dat.
Prog Zufall Astro
Prog Zufall Astro
B
Uhr
Uhr
OFF
W
OFF
W
Dat.
Dat.
Mode
Prog Zufall Astro
Mode
C
Uhr
OFF
W
Dat.
Fig. 4: Activating program memories
Fig. 5: Switching on the timer function
When program memory [C] (timer) is
The last start time that was set on the
activated and you press [Mode] again,
timer appears (e.g. 15 min, Fig. 5).
none of the three program memory
2 Briefly press the [EIN] (ON) button
symbols appears. Instead, the program
memories are deactivated, the lighting
does not react to switching times or to
The load is switched on. The timer
the twilight function but only operates
function starts. The timer period counts
in manual mode (see „Switching loads
down. The colon between the hour and
on/off manually", p. 35). You can use
minute displays flashes.
this feature, for example, to prevent the
When the timer period reaches 00:00
lighting from automatically switching
the load switches off , and the pre-set
on when it is not wanted, e. g. for a
time is again shown as the timer start
garden party.
time.
Using the timer function
You can intervene to stop the
countdown and switch off the load at
You can use the timer function to
any time:
switch on an electrical load for a pre-set
3 Press the [AUS] (OFF) button.
period. The load is switched off again
once the time set has expired.
The load switches off, and the pre-set
time is again shown as the timer start
The default start time is 15 minutes,
time.
but you can set the start time from 1
min. to 1:59 hrs yourself.
The timer function is integrated into
program memory [C].
36
memory [C] flashes in the display.
Prog Zufall Astro
ON
Uhr
Dat.
(max 1 s).

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis