FM 7
LI S T O F E R RO R S
Any errors are displayed on the display with the following codes:
NU MB E R OF
FL ASHE S
Battery protection cut-out
R0.1
(The voltage is outside the cut-out setting).
Fan over-current cut-out
R0.2
(The fan loads the electronic unit with more than 1A
Motor start error
R0.3
(The rotor is blocked or the differential pressure in the refrigeration system is too high
(>5 bar)).
Minimum motor speed error
R0.4
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed 1,850 rpm).
Thermal cut-out of electronic unit
R0.5
(If the refrigeration system has been too heavily loaded, or if the ambient temperature
is high, the electronic unit will run too hot).
R0.7
Faulty temperature sensor, or not properly connected to the control unit