Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
The shower system may only be used for bathing, hygienic and body cleaning
purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be oberserved.
• If the water connections are not stabil mounted, the fitting must be fixed with extra
screws (see page 31 Fig. A1 - A17, see page 36 Fig. A1 - A11). With this type of
installation, take care not to puncture the water pipe! If the water connections
are stabil mounted, no extra screws are required (see page 32 Fig. B1 - B14, see
page 37 Fig. B1 - B12).
Thermostatic mixer in conjunction with combination boilers
If fitting a hand shower remove the water limiter from the shower.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking water!
Fault
Insufficient water
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
Spout temperature does not correspond with tempera-
ture set
Temperature regulation not possible
Shower or spout dripping
Instantaneous heater didn't work
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Water pressure to low
- thermo cartridge calcified
- Dirt or sedimentation on valve seat, shut-off unit dam-
aged
- Flow limiter in handshower isn't removed
- Shower filter seal dirty
- check valve hasn't moved back
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Safety Function (see page 34)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Adjustment (see page 34)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Maintenance (see page 36)
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
• The check valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least
once a year).
Operation (see page 35)
Dimensions (see page 38)
Flow diagram (see page 38)
Shower outlet 1B resistance 25 l/min (0,3 MPa)
Tub outlet
Spare parts (see page 39)
Cleaning
see enclosed brochure.
Test certificate (see page 40)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-
thermo cartridge
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 65 ºC
- Exchange thermo cartridge
- Clean or exchange shut-off unit
- Remove flow limiter
- Clean filter seal between shower and hose
- Exchange check valves