6.
Tighten two M4X12
screws on the right
side and two M4X12
screw on the left side
to fix the appliance
(two people to
assemble).

OPERATION

Connect to supply power, push the ON / OFF (0 / I)
button located at the right side of the appliance to
switch on the appliance. Buzzer will have a short "D"
sound and full screen display will light up for 1 min,
then automatically switch to standby mode. Push ON /
OFF button again, if you want to switch off.
1
2
SET
3
4
ON
5
6
OFF
7
Control panel
M4X12 4PCS
OK
Set date and time:
The date and time setting can be done only when the appliance is in standby mode.
1. SET THE DAY
Press SET for 3 seconds, the day icon (1 2 3 4 5 6 7)flashes. Use + and - to set
current day. Then press OK, the hour setting automatically.
2. SET THE HOUR
The hour icon 01:00 flashes. Use + and - to set hour. Then press OK, the minute
icon 00:01 flashes. Use + and - to set minutes. In the end ,press OK to confirm and
save automatically.
Manual mode:
Press
,start at 500W (show
on screen), you can do the following:
1. SET TEMPERATURE
Press SET once, the screen will flash 20 °C (default temperature is 20 °C) Use + or
– to set temperature (5-40 °C) and then press OK to confirm setting
When temperature setting finish, the screen will automatically display the setting
temperature in working mode (SET icon and the setting temperature will light up).
Press OK to read room temperature. It will automatically switch back to setting
temperature in 5 seconds. The screen will display room temperature in standby
mode. (SET icon will not light up when room temperature is displayed only)
Note:
1. The temperature SET should be higher than the room temperature (the
temperature icon on the left). Otherwise, the appliance will not start heating.
2. One the room temperature achieves the target temperature, the appliance
will stop automatically.
3. If the room temperature is 2°C less than temperature SET, the appliance will
restart.
Window mode:
Press
, icon
show on the screen:
1. When the software detected the Room Temperature drop 5°C within 10minutes,
the built - in start counting; if the room temperature is lower than or the same
as 30 minutes ago, heater automatically enter to standby mode, Window
function end. If room temperature is higher than 30 minutes ago, the heater will
continue to work, Window function also continue to test.
2. In Window mode, if you want to cancel, press the
PROGRAMM MODE:
Programming working instruction:
56 | 57
GB
for 3 seconds to cancel.

Quicklinks ausblenden: