5. TROUBLESHOOTING

5.1.
T roubles and causes of air conditioner
If one of the following malfunctions occur, stop operation, shut
off the power, and contact with your dealer.
If the system does not properly operate except the above
mentioned cases or the above mentioned malfunctions is
evident, investigate the system according to the following
procedures.
Table 5-1 Error codes displayed on the receiver display of the indoor unit or on the wired remote control
Code
Unit
1
AA
Indoor Communication failure of wire controller
2
A1
Indoor Indoor ambient temp sensor failure
3
A2
Indoor Indoor coil temp sensor failure
A5
Indoor Drain pump failure
4
A6
Indoor Indoor fan motor failure
5
A8
Indoor Indoor unit EPROM failure
6
7
A9
Indoor Communication failure between indoor unit and outdoor unit
Indoor Indoor high temp protection in heating
8
E8
Outdoor Overload protection in cooling mode
31
Outdoor IPM module protection (F0)
9
32
Outdoor IPM module hardware protection
10
11
33
Outdoor IPM module software protection
12
34
Outdoor Compressor unconnected
13
35
Outdoor Over power current protection
Over/low power voltage protection
14
36
Outdoor
Over/low main line voltage protection
37
Outdoor Outdoor module heat fins temp sensor failure
15
16
38
Outdoor IPM module high temperature limit frequency protection
17
39
Outdoor IPM module protection
C1
Outdoor Outdoor ambient temp sensor failure
18
C2
Outdoor Outdoor coil temp sensor failure
19
C3
Outdoor Outdoor discharge temp sensor failure
20
21
C6
Outdoor Suction temp sensor failure
22
C8
Outdoor Outdoor defrost temp sensor failure
E3
Outdoor High discharge temp protection
23
FH
Outdoor Low discharge temp protection
24
E1
Outdoor 4way-valve failure
25
F1
Outdoor Outdoor DC fan motor failure
26
27
H1
Outdoor High pressure switch protection
28
H4
Outdoor Low pressure switch protection
Communication failure between the driver PCB and main PCB
29
J6
Indoor
of the indoor unit
J3
Outdoor Communication failure between PCB and IPM module
30
31
3H/5H Outdoor Communication failure between main PCB and DC fan motor module
32
J7
Outdoor Main control PCB EPROM failure
3E
Outdoor DC inverter compressor running out of step
33
Please cut off the power supply when appearing the
above malfunction, check if the voltage provided is out of
range, check if the installation of air-conditioner is
correct, then electrify again after 3 minutes power off. If
the problem is still existent, please contact the local
service station or the equipment provider.