INFORMATION REQUIREMENTS
Cooling - Information requirements for air-to-air air conditioners
Indoor unit(s)
Model(s):
Outdoor unit
Outdoor side heat exchanger of air conditioner: Air
Indoor side heat exchanger of air conditioner: Air
Type: compressor driven vapour compression
If applicable: driver of compressor: electric motor
Item
Symbol
Rated cooling
Prated,c
capacity
Declared cooling capacity for part load at given outdoor
temperatures Tj and indoor 27°/19 °C (dry/wet bulb)
Tj = 35℃
Pdc
Tj = 30℃
Pdc
Tj = 25℃
Pdc
Tj = 20℃
Pdc
Degradation
co-efficient for air
Cdc
conditioners (*)
Off mode
POFF
Thermostat-off
PTO
mode
Capacity control
Sound power
LWA
level,indoor/outdoor
If engine driven:
NO
Emissions of
x (**)
nitrogen oxides
GWP of the
refrigerant
SALVADOR ESCODA SA
NAPOLES 249 P1
Contact details
08013 BARCELONA (SPAIN)
+34 93 446 27 80
Information requirements for air-to-air air conditioners
Value
Unit
10,5
kW
10,60
kW
8,10
kW
5,86
kW
2,51
kW
0,25
Power consumption in modes other than 'active mode'
-
kW
0,0161
kW
Other items
variable
55/56
dB
mg/kWh
x
fuel
input GCV
kg CO2 eq
675
(100 years)
264
ALMD-42-NHA
ALMD-42-NHA
Item
Symbol
Seasonal space cooling
energy efficiency
Declared energy efficiency ratio or gas utilisation
efficiency/auxiliary
energy factor for part load at given outdoor temperatures Tj
Tj = 35℃
EERd
Tj = 30℃
EERd
Tj = 25℃
EERd
Tj = 20℃
EERd
Crankcase heater mode
Standby mode
For air-to-air air
conditioner: air flow
rate, outdoor
measured
Value
Unit
ηs,c
245,8
%
2,79
-
4,54
-
7,75
-
10,26
-
PCK
-
kW
PSB
0,0041
kW
4200
m3/h