7.2
Actuator mounting on the
valve body
6
1. Mount actuator top (see chapter 7.1
"Installation of actuator top").
2. Move the actuator A to the open position.
3. Insert the gasket 30 into the valve
body 1.
4. Place the actuator A and seat fl ange 29
on the valve body 1 approx. 90°
anticlockwise to the desired end position
of the control medium connectors.
5. Ensure that the hole patterns of the seat
fl ange 29 and valve body 1 are aligned.
6. Tighten the hexagon nut 6 diagonally.
7. With the valve fully assembled, check
that it is working correctly and that it is
leak-tight.