address
name
+ 72.0
Ir_02_Zone_2
+ 74.0
Ir_03_Zone_2
+ 76.0
Ir_04_Zone_2
+ 78.0
Ir_05_Zone_2
+ 80.0
Ir_06_Zone_2
+ 82.0
p_on_t_Zone_2
+ 84.0
fu_tA_Zone_2
+ 86.0
h_pb_Zone_2
+ 88.0
h_It_Zone_2
+ 90.0
h_dt_Zone_2
+ 92.0
HI_S_Zone_2
+ 94.0
HI_L_Zone_2
+ 96.0
typ_Zone_3
+ 98.0
pS_tA_Zone_3
+ 100.0
AL_Zone_3
+ 102.0
hd_2_Zone_3
+ 104.0
hd_5_Zone_3
+ 106.0
Ctr_Zone_3
+ 108.0
pS_tm_Zone_3
+ 110.0
pS_of_Zone_3
+ 112.0
Hb_t_Zone_3
+ 114.0
Hb_p_Zone_3
+ 116.0
Ir_00_Zone_3
+ 118.0
Ir_01_Zone_3
+ 120.0
Ir_02_Zone_3
+ 122.0
Ir_03_Zone_3
+ 124.0
Ir_04_Zone_3
+ 126.0
Ir_05_Zone_3
+ 128.0
Ir_06_Zone_3
+ 130.0
p_on_t_Zone_3
+ 132.0
fu_tA_Zone_3
+ 134.0
h_pb_Zone_3
+ 136.0
h_It_Zone_3
+ 138.0
h_dt_Zone_3
+ 140.0
HI_S_Zone_3
36
initial
type
value
INt
180
Ct INpUt At HB CALIBrAtIoN pHASE 2 (for Ir LAMpS) (ZoNE 2)
INt
160
Ct INpUt At HB CALIBrAtIoN pHASE 3 (for Ir LAMpS) (ZoNE 2)
INt
150
Ct INpUt At HB CALIBrAtIoN pHASE 4 (for Ir LAMpS IN pA ModE)
(ZoNE 2)
INt
140
Ct INpUt At HB CALIBrAtIoN pHASE 5 (for Ir LAMpS IN pA ModE)
(ZoNE 2)
INt
120
Ct INpUt At HB CALIBrAtIoN pHASE 6 (for Ir LAMpS IN pA ModE)
(ZoNE 2)
INt
1
SWITCHING ON MODE (ZONE 2)
INt
500
MAXIMUM LIMIT OF RMS CURRENT IN NORMAL OPERATION (ZONE 2)
INt
10
proportIoNAL BANd for HEAtING or HyStErESIS IN oN-off
CoNtroL (ZoNE 2)
INt
1
INtEGrAL HEAtING tIME (ZoNE 2)
INt
0
dErIVAtIVE HEAtING tIME (ZoNE 2)
INt
200
MAXIMUM LIMIT OF MAIN INPUT SCALE (ZONE 2)
INt
200
UppEr LIMIt of SEtpoINt (ZoNE 2)
INt
40
TYPE OF PROBE, SIGNAL AND SCALE OF MAIN INPUT(ZONE 3)
INt
800
MAXIMUM PREAK CURRENT LIMIT DURING PHASE SOFTSTART
(ZoNE 3)
INt
16
SELECt NUMBEr of ENABLEd ALArMS (ZoNE 3)
INt
11
ENABLE POWER FAULT ALARM (ZONE 3)
INt
155
ENABLE trIGGEr ModES (ZoNE 3)
INt
198
typE of CoNtroL (ZoNE 3)
INt
100
dUrAtIoN of pHASE ANGLE SoftStArt rAMp (ZoNE 3)
INt
1
MINIMUM NoN CoNdUCtIoN tIME to rEACtIVAtE tHE pHASE
SoftStArt rAMp (ZoNE 3)
INt
4
dELAy tIME for ACtIVAtIoN of HB ALArM (ZoNE 3)
INt
800
pErCENtAGE HB ALArM SEtpoINt of CUrrENt rEAd IN HB CALI-
BrAtIoN (ZoNE 3)
INt
240
Ct INpUt At HB CALIBrAtIoN pHASE 0 (for Ir LAMpS) (ZoNE 3)
INt
200
Ct INpUt At HB CALIBrAtIoN pHASE 1 (for Ir LAMpS) (ZoNE 3)
INt
180
Ct INpUt At HB CALIBrAtIoN pHASE 2 (for Ir LAMpS) (ZoNE 3)
INt
160
Ct INpUt At HB CALIBrAtIoN pHASE 3 (for Ir LAMpS) (ZoNE 3)
INt
150
Ct INpUt At HB CALIBrAtIoN pHASE 4 (for Ir LAMpS IN pA ModE)
(ZoNE 3)
INt
140
Ct INpUt At HB CALIBrAtIoN pHASE 5 (for Ir LAMpS IN pA ModE)
(ZoNE 3)
INt
120
Ct INpUt At HB CALIBrAtIoN pHASE 6 (for Ir LAMpS IN pA ModE)
(ZoNE 3)
INt
1
SWITCHING ON MODE (ZONE 3)
INt
500
MAXIMUM LIMIT OF RMS CURRENT IN NORMAL OPERATION (ZONE 3)
INt
10
proportIoNAL BANd for HEAtING or HyStErESIS IN oN-off
CoNtroL (ZoNE 3)
INt
1
INtEGrAL HEAtING tIME (ZoNE 3)
INt
0
dErIVAtIVE HEAtING tIME (ZoNE 3)
INt
200
MAXIMUM LIMIT OF MAIN INPUT SCALE (ZONE 3)
comment
80992C_MSW_PROFINET_GFX4-IR_06-2014_DEU