Herunterladen Inhalt Inhalt Diese Seite drucken

Fuel Filter Cleaning - Master DC 61 Bedienungs- Und Wartungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
►6.3. CONNECTING THE ROOM THERMOSTAT
en
(optional):
it
CAUTION: THE ROOM THERMOSTAT (OPTIONAL)
ONLY WORKS WHEN THE HEATER IS POWERED BY
THE POWER CABLE.
de
CAUTION: WHEN THE HEATER IS MANAGED BY THE
es
ROOM THERMOSTAT (OPTIONAL), THE HEATER'S
SWITCH-OFF AND ON IS AUTOMATIC.
fr
Remove the plug connected to the heater and connect the
room thermostat (optional) (C Pic. 3).
nl
pt
►►7. FUEL FILTER CLEANING
da
See Pic. 4
THE FILTER MAY NEED TO BE CLEANED DEPENDING
fi
ON THE QUALITY OF THE FUEL USED.
►7.1. Remove the plug positioned on the tank (A Pic. 4).
no
►7.2. Remove the filter from the tank.
►7.3. Loosen the nut (B Pic. 4).
sv
►7.4. Remove the filter (C Pic. 4).
►7.5. Clean the filter with clean fuel; make sure you do
not damage it.
pl
►7.6. Put the filter back in the tank.
ru
cs
►►9. DISPLAY ERRORS
See B Pic. 3
hu
ERROR
sl
F0
1. The "ON/OFF" switch is turned "ON" (|) when the
tr
heater is plugged in
hr
F1
1. No fuel
lt
2. Fuel is contaminated
lv
3. Photocell is dirty or damaged
et
4. Fuel filter is dirty
5. Ignition error
ro
F2
1. Interrupted cable
sk
2. Sensor is damaged
bg
F3
1. Internal heater overheating
uk
2. Antitilting sensor intervent
bs
F4
1. Incorrect voltage
el
FF
1. No fuel
zh
2. Dirty fuel filter
3. Dirty or defective photocell
4. Dirty or defective nozzle
5. Anti-tilting sensor trip
PF
1. Flat battery
[ ]
1. Thermostat connected
2. Switching from cable to battery power supply
CAUSE
OPERATION ERROR
PHOTOCELL ERROR
TEMPERATURE CONTROL SENSOR ERROR
THERMOSTAT ERROR
INCORRECT VOLTAGE
NO SWITCH-ON AFTER THREE ATTEMPTS
FLAT BATTERY
HEATER IN STAND-BY
►►8. STORAGE AND TRANSPORT
I ORDER TO KEEP AND/OR TRANSPORT THE HEATER
IN THE BEST WAY, THE FOLLOWING PROCEDURE
MUST BE FOLLOWED:
►8.1. Empty the fuel from the tank.
►8.2. If you notice any residue, pour clean fuel into the
tank and rinse again.
►8.3. Close the tank cap and dispose of the fuel
appropriately according to the Standards in force.
►8.4. in order to keep the heater in the best way possible,
it must be kept on a level surface to prevent the escape
of fuel and in a dry place away from any possible ex-
ternal threats.
SOLUTION
1. After disconnecting the heater, see that the switch is in
the "OFF" (0) position, plug the heater in and turn the
switch "ON" (|)
1. Turn the switch "OFF" (0), refill the fuel tank
2. Turn the switch "OFF" (0) empty and refill the fuel tank.
Clean the filter using clean fuel, do not damage the
filter (SEE PARA. 6)
3. Contact the technical service center
4. SEE PARA. 6
5. Contact the technical service center
1. Contact the technical service center
2. Contact the technical service center
1. Turn the heater off, wait until it is cooled down
2. Place the heater on a level and stable surface
1. Check voltage of your electric supply system
1. Contact the technical service center
2. Contact the technical service center
3. Contact the technical service center
4. Contact the technical service center
5. Contact the technical service center
1. Recharge the battery
1. Thermostat temperature set below the room tempera-
ture
2. Automatic re-ignition

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis