5.4
SETTING THE OPERATING TYPE
The system administrator is able to specify the operating type in the LSM just once for
the whole system when placing the terminal into operation. Only one operating type
can be used per locking system.
You will find more detailed information on Modes 2 and 3 (verification) in the manual.
CAUTION: The operating type cannot be changed once the first pin code terminal in
the locking system has been programmed, otherwise all terminals in the system must
be reprogrammed, new PINs and transponders must be issued and so on. This also
affects the use of the terminal(s) in general. You should therefore plan programming
carefully in advance.
6.0
PROGRAMMING
6.1
ASSIGNMENT TO A LOCK DEVICE
The pin code terminal is assigned to a G2 lock device on a permanent basis and can
only open this device for security reasons. Complete the following steps to configure
the terminal:
1.
Create G2 lock device
2.
Highlight G2 lock device (e.g. Locking Cylinder G2)
3.
Click on „Edit -> Lock device properties"
4.
Select „Door" tab
5.
Check the „PIN code terminal" box in the „Door attribute" field
6.
Confirm by pressing „Accept".
The terminal has thus now been configured for this G2 lock device and authorised
users can now open the door using the terminal (please take into account the different
modes).
23