Operating Mode; Circulation Pump - Uponor Smatrix Move Kurzanleitung

Vorschau ausblenden Andere Handbücher für Smatrix Move:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25
UK
Menu
Display
9
trF2
CZ
10
tr1o
11
in1
DE
12
in2
13
OUSE
DK
14
OUt
15
ourF
EE
16
˚C
17
00:00
ES
18
GriP
19
PUMP
FI
20
ctrl
21
PrH
FR
22
dry
23
ALL
HR
24
End
HU
4. Use buttons - or + to change parameter settings.
5. Use buttons < or > to locate parameter 24 (End)
IT
– Exit system parameter settings.
6. Press the OK button to exit the system parameter
settings.
LT
LV
NL
NO
PL
PT
RO
RU
SE
SK
1 0
Q U I C K G U I D E
Description
Not used by Move
Not used by Move
Wired input 1, select function
Wired input 2, select function
Outdoor sensor selection
(installed/wireless/wired/etc)
Outdoor temperature, fi xed value if
outdoor sensor is not installed
Not used by Move
Display unit
Time unit (AM/PM/24H)
Valve and pump exercise
Pump start delay after the mixer
valve has closed
Forced control of the actuator
Floor/screed preheating program
Floor/screed drying program
Factory reset
Press and hold the OK button for
about 5 seconds
Exit system parameter settings

Operating mode

During normal operation, the controller is in run mode.
In run mode different operating modes can be selected,
as well as setting current time and day, and selecting a
scheduling program.
P
AUTO
0h
2
4
6
8
10
12
14
16
18
20
Use buttons < or > to change operating mode. A box
shows which mode has been selected.
Available operating modes and settings in run mode are
the following.
Icon
Operating mode
Holiday mode
Comfort mode
Automatic mode (default)
Sets operating mode according to set
scheduling program
ECO mode
Stop mode
Time and day settings
Scheduled programs menu
Heating/cooling mode (only available if
cooling is activated)
This mode requires system parameter 0 –
Type of installation being set to rEv, but
is hidden if system parameters 11 or 12 is
set to HC.

Circulation pump

If a circulation pump is connected to the controller, it
will run continuously (default setting) during normal
operation.
To change this setting, go to system parameter 19
(PUMP) – Pump start delay, in the controller.
See section Setup the system for more information.
The Move controller can receive a pump demand signal
to one of the wired inputs (input 1 or 2, parameter 11
or 12 set to C_b) from another controller in the system,
turning on or off the circulation pump connected to P1.
U P O N O R S M AT R I X M O V E · Q U I C K G U I D E