Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications; Regulatory Information - Interlogix DDI602 Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
Example
To change the detection LED setting from OFF to ON:
1.
Press the programming button three times.
2.
Wait until the programming LED turns off.
3.
The programming LED flashes once to show that the
current value is off.
4.
Press the programming button twice.
5.
The programming LED flashes twice showing that the new
value has been stored. The detector returns to normal
operation.
Resetting options
To reset the detector to the default settings:
1.
Remove the power from the detector.
2.
Press and hold the programming button (see Figure 16,
item 2).
3.
Apply the power to the detector.
4.
After the programming LED flashes, release the
programming button.
You can reset the detector either before installation, with a PP3
battery, or by applying 12 V to the unit on site.
Walk test
In walk test mode, the blue detection LED option is set to ON.
The detection LED lights each time the DDI602 detects your
presence.
To enter the walk test mode, press the programming button
once. The unit can then be aligned. The detection LED lights
on the DDI602 every time detection takes place.
The test mode ends automatically five minutes after last
detection. Alternatively, press the program button three times,
or remove and then reapply power to cancel the walk test
mode.
Note:
When you conduct a walk test, make sure that the front
cover is in place. Do not conduct walk tests with the cover
removed.
The range of the detector increases without the protective front
cover. Therefore the front cover must be fitted to establish the
correct beam pattern. Use Table 3 on page 6 to adjust the
range as necessary. Pan and tilt the lens module over the field
of view to obtain the correct coverage area.
Accessories
UTC Fire & Security can provide a handheld walk tester DI601-
WT to aid installations.

Specifications

Detection range
Programmable: 10 m / 30 ft., 20 m / 66 ft.,
or 30 m / 98 ft.
10 to 70° detection angle, 30 x 24 m /
Coverage
98 x 79 ft. coverage max.
180° pan, 90° tilt
Adjustment
P/N 1069154 (ML) • REV F • ISS 01MAR19
Fresnel lens
28 zones for each detection element, which
can be masked with the curtain sliders
Customized optics
Double silicon shielded quad element
eliminates 50,000 lux of white light
LEDs
Top red: Programming LED
Red: PIR active
Green: Microwave active
Blue: Detector alarm
Infrared: Walk tester communication
Radar frequency range
8.5 to 10.6 GHz
Operating frequency
(country specific):
DDI602-F1
10.525 GHz
DDI602-F2
10.587 GHz
DDI602-F3
9.900 GHz
Maximum power output
E.I.R.P.
DDI602-F1
27 dBm
DDI602-F2
27 dBm
DDI602-F3
14 dBm
Outputs
Silent, solid state, magnetically immune.
NO
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor.
Alarm time 5 seconds.
NC
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor.
Alarm time 5 seconds.
Power input
9 to 15 V
Current
11 mA nominal (at 12 V )
30 mA max.
Pulse count
1 or 2
Temperature
Analogue (thermistor) and digital sensitivity
compensation
adjustment
Control
Digital microprocessor with nonvolatile
memory
Walk test
Output test mode with LED indication.
Option to disable LEDs.
−30 to +65°C / −22 to 149°F
Operating temperature
Housing
High impact ABS plastic with HDPE cover,
UV stabilized
Dimensions, W x H x D
125 x 175 x 130 mm / 4.92 x 6.89 x 5.12 in.
Weight
323 g net, 549 g gross / 11.39 oz net,
19.37 oz gross
Mounting height
Variable up to 6 m / 20 ft.
Optimum height 3 m / 10 ft. for full range
Cable < 200 m / 656 ft.
Utilising all three outputs (including tamper)
— eight-core 7/0.2 mm² / 24 AWG
Cable < 500 m / 1640 ft.
Utilising all three outputs (including tamper)
— eight-core 16/0.2 mm² / 20 AWG

Regulatory information

Manufacturer
PLACED ON THE MARKET BY:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
AUTHORIZED EU REPRESENTATIVE:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
7 / 42

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Di601

Inhaltsverzeichnis