Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Setting desired values (temperature)
To adjust the desired values:
press
-
-
increase or lower the value using the buttons
confirm the new value by pressing
-
Defrost
Automatic defrost
The unit automatically defrosts 6 times per 24 hours. The internal clock is activated the
first time the unit is turned on.
To reset the automatic defrost cycle, press and hold
will show the symbol
will begin after 4 hours. During defrost, the display will show the symbol
Manual defrost
Manual defrost can additionally be activated at any time. Press
Manual defrost will begin. The display will show the symbol
NOTE!
To set or change other parameters, information can be found in the attached de-
scription of temperature control, or service personnel can be hired to perform
such changed.
Water is removed automatically as it flows through a depression in the bottom of the
unit to a water tray, where the gathered water is converted into steam.

Tips for the user

The ventilated refrigerated counter can be filled when the desire temperature
appears on the display.
Fill appropriate GN containers with prepared dishes and place them inside the
refrigerated counter or in the display.
Wait a moment before opening shelves that have just been closed.
- 28 -
for one second: the set value will begin flashing;
The unit will begin an automatic defrost cycle, and the next one
.
and
.
for over 6 seconds. The display
.
;
for over 6 seconds.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis