Herunterladen Inhalt Inhalt Diese Seite drucken

General Installation Guidelines - Interlogix ATS1201 Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
To remove a battery:
1.
Make sure that your product settings allow you to open the
cover without starting the tamper alarm.
2.
Switch off the mains power, if necessary, and remove the
cover.
3.
Disconnect the battery, sliding the product's wires off the
wire connectors. Note that depending on the battery model
the connectors may be located differently.
4.
Remove the battery from the holder.
Dispose of the battery as required by local ordinances or
regulations. See the specifications for your product or contact
technical support for information on replacement batteries.
Mounting
The unit is mounted with screws or bolts through the mounting
holes in the rear section of the enclosure.
Ensure that the unit is mounted on a flat, solid, vertical surface
such that the base will not flex or warp when the mounting
screws and bolts are tightened.
Leave a 50 mm clearance between equipment enclosures
mounted side by side and 25 mm between the enclosure and
the sidewall.
The rechargeable battery must not be fitted until the control
panel is secured to the fixing surface. Under no circumstances
should the panel be transported with a battery fitted.
Take care that wire terminals are isolated. The use of cable
ties to neatly secure cables is recommended.

General installation guidelines

The ATS1201 has been designed, assembled and tested to
meet the requirements related to safety, emission and
immunity with respect to environmental electrical and
electromagnetic interference, as of current relevant standards.
If the following guidelines are followed, the system will give
many years of reliable service.
In addition to the following guidelines, during the installation of
the ATS1201, it is essential to follow any country dependent
installation requirements of local applicable standard. Only a
qualified electrician or other suitable trained and qualified
person should attempt to wire this system to the mains or to
the public telephone network.
Ensure that there is a good earth available for the alarm
system.
Maintain a separation between low voltage and mains
supply cables. Use separate points of cable entry to the
control panel cabinet.
If the upper and/or lower cabinet entry cable holes are
used to route wiring into the control panel, always use a
proper pipe fitting system by means of an appropriate
conduit and junction box. For this purpose, use only
materials of suitable flammability class (HB or better).
For mains power connection, use the mains connector
terminal either through a permanent wiring or a flexible
mains cable to an earthed mains outlet. Always use cable
P/N 1052491 (ML) • REV D • ISS 01JUL19
ties to fix the mains cable at the dedicated fixing point
provided near the mains terminal connector.
- When installing permanent, fixed wiring, insert an easily
accessible, dedicated bipolar circuit breaker in the power
distribution network.
- Never attempt to solder mains connection wires at the
ends where they will be wired to the terminal connectors.
Avoid loops of wire inside the control panel cabinet and
route cables so that they do not lie on top or underneath of
the printed circuit board. The use of cable ties is
recommended and improves neatness of the wiring within
the box.
The battery used with this unit, must be made of materials
of suitable flammability class (HB or better).
Any circuit connected either directly to the onboard relay
contacts or to the external relay contacts through the
onboard electronic output must be rated as a SELV (safety
extra-low voltage) operating circuit.
- A mains switching relay must not be fitted inside the
control panel cabinet.
- Always place a suppression diode (e.g. a 1N4001)
across the relay coil.
- Use only relays with good insulation between the
contacts and the coil.
The minimum clearance between equipment closures is
50 mm (between equipment vents).
Only use these units in a clean environment and not in
humid air. Environmental requirements are given in
"Specifications" on page 5.
ATS1201 housing
Figure 1: ATS1201 housing
(1) Processor.
(2) Earth connection. Use also
for cable screen and lid of
box.
To conform to CEI 79-2 regulations at level 2, the use of the
pry-off tamper is mandatory (ST580 or ST590 kit).
pry-off tamper is not supplied with the product.
For detailed information on the PCB, see "ATS1201
connections" on page 4.
(3) Pry-off tamper mounting
location.
(4) Mains power connection.
(5) Back-up battery.
Note:
The
3 / 40

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis