6.

Final assembly in a separate housing

Mounting in compliance with VdS:
-
Secure the cable binders at the provided retainers (see chapter 2.1)
-
Close housing, screw down the cover with 4 screws.
-
Test the system.
-
Seal the housing by pressing the plastic seals into the screw openings on the front of the housing.
Clean the seals(free from grease) and cover with the labels (VdS imprint).
After attaching the plastic seals, the housing cannot be opened without destroying the seals.
7.

Technical Data

Rated operating voltage
Operating voltage range
Current consumption at UB=12 V DC:
-
inactive / alarm groups open, LEDs off
-
active with Honeywell 048700.17 / 048720.17
-
active with ESSER 160455.10 / 160456.10
-
analog outputs A1 ... A4, highly active
2 detector groups:
- Voltage
- Monitoring range programmable
Protection class as per EN 60529
Environmental class as per VdS
Environmental class as per EN 50131-1
Operating temperature range
Storage temperature range
Relative humidity
Weight
Dimensions:
-
circuit board
-
housing
Housing colour
Conformity
Module as per EN 50131-3, Security Grade 3, Environmental Class II
As per SES-EMA-RL-T2:2010-08
Honeywell Security Group
Novar GmbH
Johannes-Mauthe-Straße 14
D-72458 Albstadt
www.honeywell.com/security/de
Mounting and Connection Instructions Siren Module
12 V DC
10.5 V DC to 15 V DC
55 mA
max. 1 A
max. 1.1 A
500 mA
3.3 V DC, stabilized, short-circuit protected
4k to 14k, ±20% / ±30% / ±40%
IP 30
II
Class II
-10 °C to +45 °C
-25 °C to +70 °C
max. 75% non-condensing
290 g
121 x 90 mm
163 x 151 x 39 mm
traffic white (similar to RAL 9016)
P00182-10-002-05
2016-02-03
© 2016 Novar GmbH