Assembly
Important! The fitting must be installed,
flushed and tested after the valid norms.
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the sink.
3. Slip the plastic washer, the slide washer, the metall
washer and collar over the hoses and threaded
base and tighten the collar nut by hand. If there
is not enough space, please use only the slide
washer and the metal washer without the plastic
washer.
4. Tighten screws.
5. Connect the back flow preventor cartridge to the
angle valve. Connect the connecting hose to the
back flow preventor cartridge (see page 4).
6. Connect the hose with hose nut, taper sleeve,
disc and washer (see page 4).
7. Mount the hose weight - be careful by the max.
drawn out, otherwise the hose could be crack.
After the assembly!
8. Dismount the handspray.
9. Flush through the hose.
10. Mount the handspray.
11. To connection down, hand-screwed (1 Nm).

Operation

The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
The handspray can be drawn approx. 50 cm out
of the arm lining. The spray mode is changed to
showerspray by pressing the front button
top of the sprayhead. By releasing the button the
spray mode changes to aerated spray.
English
Technische Daten
Operating pressure:
Recommended
operating pressure:
Rate of flow spray former: ca. 5.0 l/min 0.3 MPa
Rate of flow needle spray:ca. 4.5 l/min 0.3 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended
hot water temp.:
Back flow and vacuum breaker
Achtung!
With water heaters of 5 liters the flow rate at the
mixer should not exceed 5 l/min.
In this case the flow rate must be reduced at the
isolation valve.
When the storage tank is being heated, the spout
will drip.
When changing the spray former, it is imperative to
use one made for this type of mixer.
Maintenance non return valve
The non return valves must be checked regularly ac-
cording to DIN EN 1717 in accordance with national
or regional regulations (at least once a year).
Spare parts (see page 3)
1
handle
1.1 screw cover
on the
2
flange
3
nut
4
cartridge cpl.
5
hose
6
handspray
7
spray former cpl.
8
fixing set
9
connection hose 600 mm
XXX = Colors
000 chrome plated
800 stainless steel optic
max. 1 MPa
0.1 - 0.5 MPa
max. 80° C
65° C
14890XXX
96338000
96391XXX
94194000
92730000
96267000
14892XXX
94033000
95049000
97398000